Programming instructions
- 355 -
DX-120 Programming Manual PROGRAMMING UCDS
Programming UCDs via the DET (continued)
Setting the UCD Overflow 2 Destination:
From the DB Item Select screen (see steps 1 through 3 on page 349):
4) Enter 06-01-XX-10 (where XX represents the UCD group: 01~24).
5) Press save to display the Overflow 2 Destination screen for the specified UCD group.
6) Press chg.
7) Enter the UCD directory number to which want the system to send the queued caller when the overflow 2
timer has expired.
• Valid options include any valid extension or UCD directory number.
• The default is NULL.
8) Press save to store the setting.
• If the destination is a third-party RAD device that is connected to a DX-80 analog port, enter that port
number here. If the destination is the DX-80 optional integrated voice mail, enter extension number
433.
9) Press next to display the UCD Overflow Count screen (now to go step 6 in“Setting the UCD Overflow
Count:” below).
OR
HINT
If you want to set the Overflow 2 Destination for other UCD groups, press the volume
Up button to return to the DB Item Selection screen, and repeat the steps in this
section.
Press the volume UP button to return to the DB Item Selection screen.
OR
Exit programming (see “Exiting Database Administration” on page 27).
Programming UCDs via the DET (continued on next page)