Programming instructions

- 335 -
DX-120 Programming Manual BASIC TOLL RESTRICTION PROGRAMMING TASKS
Class of Service and Digit Intervals via the DET (continued)
Restricting Calls by CO Line COS:
From the DB Item Select screen (see steps 1 through 3 on page 333):
4) Enter 05-01-X-NNN-04 (where X is the tenant group: 1~3; and NNN is the restriction number you want to
program: 001~100).
5) Press save to display to display the COS CO LN.
6) Press show to display the Day Allowed screen.
7) Press show again to display the COS screen.
8) Press chg to set the toll restriction on for currently displayed class of service (Y/N).
AND/OR
Press next until the COS you want to change displays.
9) Press next to display the DAY Allowed parameter screen for the CO Line COS (now go to step 6 in
“Restricting Calls by CO Line COS:” below).
OR
Press the Hold button to return to the Day Allowed screen.
HINT
You can then press next to display the Eve Allowed screen. Once you do that, repeat
steps 7 and 8 above for the Evening Allowed COS setting.
OR
Press the volume UP button to return to the DB Item Selection screen.
OR
Exit programming (see “Exiting Database Administration” on page 27).
Programming the Specific Extension COS:
From the DB Item Select screen (see steps 1 through 3 on page 333):
4) Enter 01-XXX-NN (where XXX is the extension: 101~204; and NN represents 05 is DAY Class Of Service
and 06 is EVE Class Of Service).
5) Press save to display the extension COS screen.
6) Press chg until you see the COS you want to assign for the selected service mode.
7) Press the Hold button to return to the previous menu level.
OR
Press the Volume button (up or down) to return to the DB Item Selection screen.
OR
Exit programming (see “Exiting Database Administration” on page 27).