Programming instructions
- 225 -
DX-120 Programming Manual BASIC CALL HANDLING PROGRAMMING TASKS
Establishing Dialing Ratio via PC-DBA (continued)
2) Select the information for the fields as described below:
When you are finished:
3) Click the Update button to store the settings into the database on the local disk.
4) Click the Close button to exit the current screen and return to the PC-DBA main screen.
When you have finished all programming changes:
5) Perform a SEND to copy the database changes to the DX-120 switch system memory.
Establishing Dialing Ratio (continued on next page)
FOR THIS FIELD... SELECT...
Break Time
The length of time you want the system to play each individual pulse
during out-dialing from the Break Time field.
• Valid choices are 60 or 67 milliseconds.
• The default is 60 milliseconds.
Inter-Digit
The time you want the system to pause between each pulse during
out-dialing.
• Valid choices are 400 - 800 milliseconds, in increments of 50
milliseconds.
• The default is 800 milliseconds.
Tone Time
The length of time you want the system to play each individual DTMF
tone during out-dialing.
• This time is also used for time between DTMF digits.
• Valid options are 70, 90, or 120 milliseconds.
• The default is 70 milliseconds.