Programming instructions
- 215 -
DX-120 Programming Manual BASIC CALL HANDLING PROGRAMMING TASKS
Setting Up Transfer Recalls for Idle and Busy Extensions via PC-DBA (continued)
In the XFR B (Busy) and XFR I (Idle) Recall fields on the right side of the screen:
2) Enter/select the information in the fields as described below:
When you are finished:
3) Click the Update button to store the settings into the database on the local disk.
4) Click the Close button to exit the current screen and return to the PC-DBA main screen.
When you have finished all programming changes:
5) Perform a SEND to copy the database changes to the DX-120 switch system memory.
Setting Up Transfer Recalls for Idle and Busy Extensions (continued on next page)
IN THIS FIELD... SELECT...
XFR_B Recall
The length of time that you want the system to ring a busy extension
before pulling the call back.
• Valid options include 16, 30, 60, 90, and 120 seconds.
• The default is 60 seconds.
XFR_I Recall
The length of time that you want the system to ring an idle extension
before pulling the call back.
• Valid options include 16, 30, 60, 90, and 120 seconds.
• The default is 30 seconds.