Programming instructions

BASIC CALL HANDLING PROGRAMMING TASKS DX-120 Programming Manual
- 200 -
Specifying Pause Time via PC-DBA (continued)
1) Go to ProgrammingXCall HandlingXTiming to display the Call Handling—Timing screen.
In the Pause Time field in the center column:
2) Select the timing you want to use.
• Valid options are from 0.5 to 7.0 seconds.
• The default is 2.0 seconds.
In the PBX Auto Pause field in the third column:
This field allows you to set the auto pause insertion time (used with PBX type CO line ports).
3) Select the timing you want to use.
• Valid options are from 0.5 to 7.0 seconds.
• The default is 1.0 second.
When you are finished:
4) Click the Update button to store the settings into the database on the local disk.
5) Click the Close button to exit the current screen and return to the PC-DBA main screen.
When you have finished all programming changes:
6) Perform a SEND to copy the database changes to the DX-120 switch system memory.
Specifying Pause Time (continued on next page)