Programming instructions
UPGRADING AN EXISTING SYSTEM DX-120 Programming Manual
- 6 -
Converting an F39 DB file to an F03 DB file (continued)
OTHER DIFFERENCES WHICH MAY AFFECT CONVERTING
• F39 has 60 Extensions while F03 has 120
• Only 60 Extensions settings will be copied to F03 database file. You should set others manually.
• F39 has 16 C.O.Line while F03 has 40 C.O. lines
• Only 16 C.O.Line settings will be copied to F03 database file. In the category Extension, only first 16 records
about “Receive Assign” and “Line Access Assign” will be copied. You should set others manually.
NOTE
C.O. lines for DX-120 are 800-839 (C.O. lines 840 through 843 are reserved for future
use).
• System Resource - SPD NO.
• Since the assignment of SPD NO. in F39 may causes conflict, some setting may be ignored. You'd better double
check it after converting
SOME ITEMS ARE NOT COPIED IN ORDER TO AVOID CONFLICT
These items should be set manually.
• C.O.Line - C.O.Group
• System Application – Numbering Plan
• C.O.Line - C.O.Group
• System Application – Numbering Plan
POSSIBLE ERRORS DURING CONVERSION
The following is a list of possible errors that may occur during the conversion of the DX-80 database. If any of these
occur, you will need to set the specified information manually.
INDEX DESCRIPTION
C001 This item exists in F03, but not in F39.
C002
This item has probably been converted, but some conflict may generate because of the differ-
ences between F39 and F03. Double check it after converting, and set manually as needed.
C003 This item was not be converted because of the data conflict.
C004 Exception occurred during conversion.