Programming instructions
- 123 -
DX-120 Programming Manual BASIC CO LINE PROGRAMMING TASKS
Setting Day and Evening COS and MOH Source (continued)
SETTING DAY AND EVENING COS AND MOH SOURCE VIA THE DET
NOTE
• chg, bksp, save, one, always, del, and ack are interactive LCD button operations.
Use the three buttons below the LCD display to activate the associated operation.
• You can press Hold at any time to return to the previous level or press the volume
buttons to return to the main DB selection screen.
1) Enter Database Administration (see page 26) using the feature code Feature # * to display the password
prompt.
2) Enter the DB Admin password (see page 27).
3) Press show to display the DB Item Select screen.
4) Assign the day and evening classifications for the CO line
5) Enter 02-XXX-04 (where XXX is the CO line directory number: 800-839).
6) Press save to advance to the Day Classification programming screen for the CO line you entered (CO line
1 = 800, CO line 40 = 839).
7) Press chg until the appropriate day class (0 through 7) appears.
• The default is 0.
8) Enter 02-XXX-05 (where XXX is the CO line directory number: 800-839).
9) Press save to advance to the Evening Classification programming screen for the CO line you entered (CO
line 1 = 800, CO line 40 = 839).
10) Press chg until the appropriate evening class (0 through 7) appears.
• The default is 0.
11) Enter 02-XXX-06 (where XXX is the CO line directory number: 800-839).
12) Press save to advance to the MOH Source programming screen for the CO line you entered (CO line 1 =
800, CO line 40 = 839).
13) Press chg until the appropriate MOH source (MC1, MC2, Tone) appears.
14) Press the Hold button to return to the previous menu level.
OR
Press the volume UP button to return to the DB Item Selection screen.
OR
Exit programming (see “Exiting Database Administration” on page 27).