Installation manual
– 13 –
5.4 Start-Up Flush
Open lower front door to access filter assembly, turn the water on at the
piercing valve. This brings water to the ball valve. Disconnect the orange tubing
from the bottom of the 2nd stage carbon filter and place a pan or bucket under-
neath the filter to catch water. Open ballvalve inside the cooler 1/4-turn (handle
in line with tube is “on”). and let water flow through filters into the bucket or pan
to push out air and carbon fines. When water runs clear, turn off ball valve and
re-connect the orange line to the filter .
Turn on the water to the filter system by opening the ballvalve inside the cooler
1/4-turn (handle in line with tube is “on”). Check all connections to assure there are
no leaks. CAUTION. DO NOT TURN ON HOT OR COLD POWER CON-
TROLS YET.
Remove the top cover of the PureWaterCooler™ by removing 2 screws from
back of top cover. Pull the cover off, exposing the main tank. The 1000 & 1010 unit
use a mechanical float valve to control flow to the tank. The unit does not have to be
plugged in to start water flow.
Water will flow into the main tan/cold tank and then the hot tank as well. Let
cooler tanks fill with the filtered water until full - about 2-hours for the ‘R’ version,
about 10-15 minutes for the ‘F’ version.
Observe the water level when full, and see that water input to the tank stops
when it is full.
Figure 9
Back view of Cooler Water Connections Model 1000