IntrInsIc safety 
(
Is
)
 InformatIon
IS version  of the 
VX-450
 series  is equipped with  any of the following  optional units, meets  the requirements of 
ANSI/UL 913 5th Edition for Class I, II, III, Division 1, Groups C, D, E, F, G, T3C hazardous locations.
  Battery Packs: 
FNB-V113LIIS
  Speaker Microphone: 
MH-66
A4B
  VOX Headset: 
MH-81
A4B
  Man Down Alert with Digital Voice Storage Unit:
DVS-9
  ANI & Encryption Unit: 
FVP-44
r
  Never charge the battery in the hazard areas.
r
  Never install/removal the battery in the hazard areas.
r
  Never install/remove the optional unit (includes the Speaker/Microphone and VOX Headset) in the hazard areas.
r
  The 
VX-450
 shall not be directly installed or used in any process where its enclosure might be electrostatically 
charged by the rapid ow of a non-conductive media.
r
  Ensure that there is no external damage to the radio, antenna or battery before entering the potentially explosive 
atmospheres, as  it  might compromise the safety of  the  unit. eg an antenna with  a  damaged end or insulation 
must be replaced before use in any potentially explosive atmospheres.
r
  Substitution of components may impair intrinsic safety. Installation of 
FNB-V113LIIS
 does NOT convert nor-
mal 
VX-450
 into IS version.
r
To acquire the IS version of the 
VX-450
 series you much select the Intrinsically Safe battery option at the time 
of purchase.