Security Camera User Manual
VerteX RTH Series   H.8 and H.16 Series 
    53   
real time. Five commands can be executed. Depending on the S/W status, however, some commands cannot be 
executed. 
New 
Returns the status of the selected storage device to New; if this command is executed, the 
selected storage device will be moved to the {New} storage device manager. 
Online 
Changes the selected storage device in online state. 
Offline 
Changes the selected storage device in offline state. 
Format 
Format the selected storage. 
Eject 
Separates the selected device completely from the software. 
※  Physical states supporting the execution of the commands above include Healthy and 
Warning. In fault state, however, no command can be executed. 
When removing a hard disk installed in the DVR or storages connected to USB 
port, the user shall execute the {Eject} command. 
  Backup 
The backup storage is managed in Backup. Backup storages are not used to store data; rather, they are only 
used to back up data. The user can execute only the {New} command. 
Depending on the storage type, the storage is used only for {Direct} or {Backup} 
purposes. 
(2)  Configuration of the local storage device 
Model 
Model name of the storage device. 
Serial 
Serial number of the storage device. 
Location 
Physical location of the storage device. 
Capacity(T/F) 
Storage device capacity (T: Total; F: Free) 
Status(SW/HW) 
Storage device status (SW: Software; HW: Hardware) 
※  There are three software status types. 
Active 
Connected to storage or backup device; currently saving the data. 
Online 
Only connected to storage or backup device. 
Offline 
Not connected to storage or backup device. 
※  There are three hardware status types. 
Healthy 
Connected to storage or backup device; functions normally. 
Warning 
Connected to storage or backup device, but error was detected; in this case, data 
storing or backup cannot be made (for more information, see the description below). 
Fault 
Not connected to storage or backup device; cannot perform data saving or backup. 
B.  Operation after adding a local storage device 
1.  Fault State:  The storage device is completely damaged, and none of the S/W operations 
can be performed. The fault state is not related to a DVR problem. The DVR has detected the 
fault and stopped the recording. 
2.  Warning State: The storage device has a physical error that can be corrected by the storage 
device or by the DVR. If the error is not taken care of, however, the storage device is likely to 
be damaged (and shift to fault state). Backing up data in the corresponding storage device and 
replacing the device with a normal one are strongly recommended. 
3.  If there is an active storage device with a warning or a fault, a message is displayed on the 
upper left part of the screen. 










