4. User Manual of the Rayocomp PS 1000 Polar Rayonex Schwingungstechnik GmbH Sauerland-Pyramiden 1, 57368 Lennestadt Tel.: 02721 / 6006-0 FAX: 02721 / 6006-66 Internet: www.rayonex.de / e-mail: info@rayonex.de Art.-Nr.: 9000EN • FB-069 • Rev3 • Stand: 10.08.
Contents 1. Basic Questions Concerning the Rayocomp PS 1000 Polar Page 1-1 1.1 Why does the Rayocomp PS 1000 Polar have a modular construction? Page 1-1 1.2 What do you have to regard when switching the Rayocomp PS 1000 Polar on or off? Page 1-2 1.3 What are the basic rules concerning the operation of the Rayocomp PS 1000 Polar? Page 1-3 1.4 How can I enter a text in the Rayocomp PS 1000 Polar? Page 1-6 1.5 How can I enter an interference value in the Rayocomp PS 1000 Polar? Page 1-7 1.
2.2.7 How do I test the 51 most important resonance spots of the body and determine a complete overview of the energetic blockades of the organism with the check-up list? How do I test disorders caused by electric smog, geopathy, bacteria, viruses and parasites or an unbalanced acid-base equilibrium? 2.3 Questions concerning the secondary menu point “Chakra activation” Page 2-18 Page 2-22 2.3.
2.6.5 How can I transform the contents of the memory into an own, permanently integrated program? Page 2-43 2.6.6 How can I add an integrated program to the memory contents? Page 2-44 2.6.7 How can I add the values of an external memory card to the contents of the memory , and how can I delete a memory card and save the contents of the memory on the empty memory card? Page 2-45 2.6.8 How can the values of the memory contents be printed? Page 2-46 2.
. Module “Harmony with Sounds of Nature and Music” – Questions Page 5-1 5.1 How can I play a single music title? Page 5-2 5.2 How can I play a series of music titles at random? Page 5-3 5.3 How can I apply harmonizing programs and play matching music titles simultaneously? Page 2-33 6. Patient History – Questions Page 6-1 6.1 What are the advantages of the patient history in the Rayocomp PS 1000 Polar? Page 6-2 6.
7.2 System setup – Questions Page 7-9 7.2.1 How can I store the name of my practice in the Rayocomp PS 1000 Polar? Page 7-9 7.2.2 How can I provide read and write protection for my memory cards, delete them completely or gain information concerning a certain memory card? Page 7-10 7.2.3 How can I alter the time and value setup of the Rayocomp PS 1000 Polar? Page 7-12 7.2.4 How can I enter my own interferences? Page 7-13 7.2.
User Manual Rayocomp PS 1000 Polar 1. Page 1-1 Basic Questions Concerning the Rayocomp PS 1000 Polar 1.1 Why does the Rayocomp PS 1000 Polar have a modular construction? If you take a close look at the market, you will find an extra device for each different application variation of oscillation medicine. For the user, this can only mean, he has to buy a new device for each single method and also to provide sufficient space for each device.
User Manual Rayocomp PS 1000 Polar 1.2 Page 1-2 What do you have to regard when switching the Rayocomp PS 1000 Polar on or off? In the rear part of the Rayocomp PS 1000 Polar, you will find the on/off switch (see arrow) of the device. Switching-on Please never switch on the Rayocomp PS 1000 Polar, before the temperature of the device has been adapted to the surrounding temperature.
Page 1-3 User Manual Rayocomp PS 1000 Polar 1.3 What are the basic rules concerning the operation of the Rayocomp PS 1000 Polar? After switching on, the device displays the following main menu: 3 1 4 2 5 6 6 6 6 6 6 Caption 1: The name of the device Caption 2: Here you can see the patient name, if a patient has been selected, otherwise the user’s name, i.e. practice Dr. Mustermann, is displayed (see also questions 6.4 and 7.2.1). Caption 3: This is the Help key.
User Manual Rayocomp PS 1000 Polar 4 Page 1- At any time, when you are working with interferences, this can be seen in the right margin of the monitor. The following figure shows the five interferences set for Chakra harmonization (see caption 1). Because the Rayocomp PS 1000 Polar can set five different interferences at the same time, all five are displayed for your information. 1 2 In the lower right margin of the monitor (see caption 2), you can see the four keys of the polariser.
User Manual Rayocomp PS 1000 Polar Page 1-5 3 4 5 6 2 7 8 1 9 10 Caption 1 indicates the actual selection window, in which you can find all selectable descriptions. The description you have currently selected is always in the box with the grey background, see caption 2. If you were to confirm this selection (this is always done with the central one of the navigation keys arranged on the right side, caption 7), the program course would be continued with A 01 Lung Meridian.
Page 1-6 User Manual Rayocomp PS 1000 Polar 1.4 How can I enter a text in the Rayocomp PS 1000 Polar? Several places in the application allow the entry of a text. An external keyboard is not available, therefore a keyboard has been programmed in the device. This picture serves as an example: 1 2 3 4 5 6 7 In the upper part of the monitor (see caption 1), a description of the anticipated text always appears. In this case, the name of the program (i.e. an own harmonizing program) should be entered.
Page 1-7 User Manual Rayocomp PS 1000 Polar 1.5 How can I enter an interference value in the Rayocomp PS 1000 Polar? Several places of the application allow the entry of interference values. An external keyboard is not available, therefore a keyboard has been programmed in the device.
Page 1-8 User Manual Rayocomp PS 1000 Polar 1.6 How can I enter treatment periods in the Rayocomp PS 1000 Polar? In some parts of the application, you have the possibility of setting different incentive rates, i.e. the time for desensitisation. An external keyboard is not available, therefore a keyboard has been programmed in the device.
User Manual Rayocomp PS 1000 Polar Page 2-1 2. Questions concerning the Bio-Resonance according to Paul Schmidt – Human Medicine – The questions in this chapter relate to the key of the main menu marked with an arrow: Note: We would like to remind you, that certain functions i.E. the Bioenergetics according to Manfred Denecke do not belong to the standard equipment. Item 7.1.4 informs you, how to look into the integrated modules in the Rayocomp PS 1000 Polar.
Page 2-2 User Manual Rayocomp PS 1000 Polar 2.1 Questions concerning the secondary menu point “Direct” 2.1.1 How can I enter, test and harmonize interferences very quickly with the function “Direct”? After you have pressed the key Bio-resonance according to Paul Schmidt in the main menu, please activate the key marked with an arrow. As a result, the following page is displayed: 3 In the menu point Direct, 1 you can enter a total of five interferences.
Page 2-3 User Manual Rayocomp PS 1000 Polar 2.2 Questions concerning the secondary menu point “Testing” 2.2.1 How does the testing process with the sensor (Rayotest) and the integrated polariser work in the Rayocomp PS 1000 Polar, and how can I find out, whether an energetic disorder is weak or very strong? The basic disclosures for polarisation can be found in the second part of this user manual, therefore the practical application with the device will be explained in the following.
Page 2-4 User Manual Rayocomp PS 1000 Polar When the Start key is pressed, the interferences can be seen on the right side, and also the four polariser keys. The basic set up of the polariser is always N = neutral, which means without polarisation. In caption 1, the current state of the associated resonance is displayed. In the display mode, all resonances are set to n.t., which means not tested. If a new resonance is being tested, the resonance property is set to i.O.
Page 2-5 User Manual Rayocomp PS 1000 Polar In this way, you must test all the interferences offered to you. If you are unsure, whether you have skipped an interference by mistake, you can press the button of the sensor to the left, and you return to the previous interference. If you have already defined a patient in the patient history before testing, these values are automatically stored when leaving the test and can be called up or tested again later on.
User Manual Rayocomp PS 1000 Polar Page 2-6 2.2.2 How do I test the interference values of the memory ? There are many reasons for testing the values in the memory . For example, they can be values from a memory card, an own compilation, or a special therapy program. Perhaps you want to test the special program Parasites; in that case, you should first load the corresponding program from the memory management and then test the memory values.
User Manual Rayocomp PS 1000 Polar Page 2-7 2.2.3 How do I carry out the most successful patient test, the range value test? The range value test is the perfect method for testing very complex symptoms or disorders, which are particularly difficult to treat. The range value test concretely begins with the start value. This is followed by testing each interference on resonance in steps of 00.50. As a result, the range value test is a compilation of all those resonances the body needs for regulation.
User Manual Rayocomp PS 1000 Polar Page 2-8 The monitor changes to display the following page: Now test with the sensor to find out, whether you achieve a rotation (left or right motion) or a linear movement. A rotation means, that the field in the organism linked to the interference is stable and therefore does not require treatment. If, however, the achieved motion is linear, this patient suffers from an energetic blockade.
User Manual Rayocomp PS 1000 Polar Page 2-9 2.2.4 How do I test individual indications comfortably, without having to use written indication lists? In the past, the single indications had to be looked up in corresponding indication lists in order to find the right diagnosis, but now the Rayocomp PS 1000 Polar offers a very comfortable solution. The instantaneously available indication values are already integrated in the device and can be called up very easily.
User Manual Rayocomp PS 1000 Polar Page 2-10 2.2.5 How do I test the global test set with a total of 70 allergen compilations, in order to receive a complete picture of the intolerances of the patient? Generally: The global test set presents itself as a highly condensed test set with a total of 70 ampoules. Each one of the test ampoules contains a great number of single substances.
User Manual Rayocomp PS 1000 Polar Page 2-11 G10:Meat, tofu G11:Fish, shellfish and molluscs G12:Grains, rice, seeds G13:Pulses, kernels G14:Sugar, honey, liquorice G15:Artificial sweeteners, sugar surrogates G16:Salt, curing substance, iodide, fluoride G17:Seasoning, vinegar G18:Spices G19:Herbal teas G20:Coffee, tea G21:Baking ingrediences G22:Nuts G23:Edible mushrooms G24:Beer, wine, brandy G25:Tuberous vegetables G26:Vegetables, melons G27:Pomaceous fruit G28:Stone fruit, exotic fruit G29:Berries G30:
User Manual Rayocomp PS 1000 Polar Household, Cosmetics: G43:Household, cosmetics Textiles, Textile Colorants, Detergents: G44:Textiles, natural fibres G45:Textiles, man-made fibres G46:Textile colorants G47:Detergents, fabric conditioners Medical Substances: G48:Antibiotics, antiseptic and antimycotic agents G49:Corticoides G50:Local anaesthetics, substances for eye treatment G51:Antibiotics, corticoides, penicillins 1 G52:Antibiotics, corticoides, penicillins 2 G53:Various pharmaceutical products, psychi
User Manual Rayocomp PS 1000 Polar Page 2-13 Testing the Global Test Set: After you have pressed the key Bio-resonance according to Paul Schmidt in the main menu, please activate the key Test. Then press the key 70s allergen test on the left side. The picture you can see on the right appears. A monitor page becomes visible, which shows all necessary steps for preparing the allergen test.
User Manual Rayocomp PS 1000 Polar Page 2-14 The following monitor page appears: In the window, all the ampoules contained in the global test set appear. Now integrate the patient in the allergen test. Instead of the hand detector, connect an allergen detector and let your patient hold it in his left hand. The patient is still connected with the foot detectors and the right hand detector.
User Manual Rayocomp PS 1000 Polar Page 2-15 Is the present intolerance strong or weak? Now test with the sensor to find out, whether you achieve a rotation (left or right motion) or a linear movement. If you achieve a rotation, the substance cannot destabilise the corresponding field of the organism, in other words, the body has no problems with this substance. If, however, the achieved motion is linear, this patient is suffering from an intolerance of the substance.
User Manual Rayocomp PS 1000 Polar Page 2-16 2.2.6 How do I test an individual allergen? Beside the global test set, with which you can test a total of 70 so-called collection ampoules (see question 2.2.5), you also have the possibility of testing single substances on their intolerability. After you have pressed the key Bio-resonance according to Paul Schmidt in the main menu, please activate the key Test. Then press the key Individual allergen test on the left side.
User Manual Rayocomp PS 1000 Polar Page 2-17 Now integrate the patient in the allergen test. Instead of the hand detector, connect an allergen detector and let your patient hold it in his left hand. The patient is still connected with the foot detectors and the right hand detector. Now the patient touches the ampoule filled with the substance, which is going to be tested. If you only want to test a few ampoules, you can also place the ampoule into the protection cup of the device.
User Manual Rayocomp PS 1000 Polar Page 2-18 2.2.7 How do I test the 51 most important resonance spots of the body and determine a complete overview of the energetic blockades of the organism with the check-up list? How do I test disorders caused by electric smog, geopathy, bacteria, viruses and parasites or an unbalanced acid alkaline equilibrium? In this program version, the Rayocomp PS 1000 Polar supports a total of six different test windows. 1.
Page 2-19 User Manual Rayocomp PS 1000 Polar As an example, the geopathy test is explained in the following. Currently, the interferences shown in the display (see caption 1) are in the display mode (see caption 2). In the display mode, you can look at the interference values and their resonances with the help of the navigation keys without setting every single value first. This 5 function is particularly useful if you want to look at a previous test and its results from the patient history.
User Manual Rayocomp PS 1000 Polar Page 2-20 Before beginning with the testing process, please consider, whether you are testing yourself or a third party, i.e. a patient. In part 2 of the user manual, you will find valuable information to assure exact measuring. Now test with the sensor to find out, whether you achieve a rotation (left or right motion) or a linear movement. A rotation means, that the field in the organism linked to the interference is stable and therefore does not require treatment.
Page 2-21 User Manual Rayocomp PS 1000 Polar In the following, you will find a summary of the functions of the sensor: Spring wire Storing an N-resonance Previous interference value Alter polarisation Next interference value Sensor button Handle, wood Note: During the process of testing, do not hold the Rayotest immediately next to the patient or above the device.
User Manual Rayocomp PS 1000 Polar 22 Page 2- 2.3 Questions concerning the secondary menu point “Chakra activation” 2.3.1 How can I carry out a rapid or very intensive activation of the Chakras of a female or a male patient? Basically, the Chakras describe the most important energy transformation centres of the body. The importance of active Chakras has found a lot of attention in literature.
Page 2- User Manual Rayocomp PS 1000 Polar 23 Quick Harmonization: Quick harmonization is carried out in two harmonizing steps. In the first step, the four left-rotating Chakras of a woman are harmonized and in the second step, the same goes for the three remaining right-rotating Chakras. At first, the four right-rotating Chakras of a male patient are harmonized, while the three left-rotating Chakras are harmonized in the second step. A five minute treatment is fully up to the mark.
User Manual Rayocomp PS 1000 Polar 24 Page 2- Important information concerning the rotational direction of the Chakras: Surely you have noticed, that the Chakras rotating to the left are harmonised with the polariser switched to + (right rotation). There is a special reason for this, the mirror effect. The Vertex Chakra of a man, for example, has a right rotation, but if you stand in front of him, you see a left rotation (mirror effect).
User Manual Rayocomp PS 1000 Polar 25 Page 2- 2.3.2 How can I explain the test with the connected sensor (one-hand rod) to the patient with the aid of the “Chakra activation”? A patient, who is being tested with the Rayocomp PS 1000 Polar with the connected sensor for the first time, will easily understand the test method, if you demonstrate the Chakra activation.
User Manual Rayocomp PS 1000 Polar 26 Page 2- Chakras (Sanskrit: Chakra = wheel) are rotating energy fields, which integrate many smaller energy fields, therefore taking over a higher control function. Beside the main Chakras, which are the central control fields, the body has a large number of smaller rotating energy fields. These small secondary energy fields, which can be detected with the rod all over the body, can be seen as mini- or side-Chakras. The Tibetan medicine recognises 76,000 Chakras.
User Manual Rayocomp PS 1000 Polar 27 Page 2- 2.4 Questions concerning the module acupuncture with oscillations. Traditional Chinese Medicine (TCM) knows of 14 Meridians, their frequencies were examined and determined, together with the points belonging to them. Today, we are able to balance every single Meridian point without using needles, merely with the aid of the Rayocomp PS 1000 Polar and the integrated polariser.
User Manual Rayocomp PS 1000 Polar 28 Page 2- The page appearing on the screen shows you a test window, which offers the possibility of testing the 14 Meridian points. The tests are not carried out at the location of the Meridian points, the patient is connected to the hand and foot detectors instead. The test method will not be explained here again, you can look it up in the answer to question 2.2.1, where you will find a very detailed description.
User Manual Rayocomp PS 1000 Polar 29 2.4.2 Page 2- How can I test an individual meridian, point by point? Each Meridian is a collection of several single Meridian points. The frequencies of each single one of these points has been described, therefore they can be harmonised with the Bio-resonance according to Paul Schmidt. After you have pressed the key Bio-resonance according to Paul Schmidt in the main menu, please activate the key Acupuncture with oscillation.
Page 2- User Manual Rayocomp PS 1000 Polar 30 As soon as you have pressed the key Meridian test, the first point of the lung Meridian is displayed in a graph as a red dot. Now you can test the patient via hand and foot detector, but also directly by touching the indicated point of the patient body with a spherical detector.
User Manual Rayocomp PS 1000 Polar 31 2.4.3 Page 2- How can I harmonize an individual compilation of meridians? The Rayocomp PS 1000 Polar, equipped with the module acupuncture with oscillations, provides a function, with which to harmonize an individual compilation of Meridian points. After you have pressed the key Bio-resonance according to Paul Schmidt in the main menu, please activate the key Acupuncture with oscillation. Then press the key marked with an arrow.
User Manual Rayocomp PS 1000 Polar 32 Page 2- Now you arrive in the harmonizing window. On the top, you can read the remaining harmonizing time. From the information line below, you can read, which Meridian is currently being harmonised. Press the Start key to begin with harmonising. If you should be testing while harmonising, you can use the keys Previous and Next to move forward and backward between the interferences and select the one you need.
User Manual Rayocomp PS 1000 Polar 33 Page 2- 2.5 Questions concerning the secondary menu point “F1” 2.5.1 How can I compose an individual harmonizing program quickly, using the integrated programs (including sounds of nature and music, if the module is integrated)? The Rayocomp PS 1000 Polar contains 54 integrated harmonizing programs of the Bio-resonance according to Paul Schmidt as a standard. Furthermore, you can integrate special programs, harmonizing programs according to Dr. med.
Page 2- User Manual Rayocomp PS 1000 Polar 34 2 4 3 1 6 8 5 7 In the lower left image field (see caption 1) you can see an arrangement of keys, which can be used to make the integrated programs, i.e. Rayonex or acupuncture, appear in the display window (see caption 2). Use the navigation keys (placed in the centre of the two display windows) to select the desired program.
User Manual Rayocomp PS 1000 Polar 35 Page 2- The pictures shows, that two programs have been selected. You can see the two programs in the right selection window. Read the following text in the first line: o.M. 00:30 R 51 Pre-control. o.M means, that the program will not be accompanied by music. If music would also have been selected beforehand, you would read the letters m.M: (with music).
User Manual Rayocomp PS 1000 Polar 36 Page 2- 2.6 Questions concerning the secondary menu point -Memory management The menu point memory management offers innumerable possibilities for interference value compilations, analysing, saving on external memory cards, defining as own program etc. The interferences compiled in the memory management can be called up for testing and harmonizing at any time later on.
Page 2- User Manual Rayocomp PS 1000 Polar 37 2.6.1 What functions are available from the Memory management? It is easy to gain access to the memory management : in the main menu, press the key Bio-resonance according to Paul Schmidt, then activate the key Memory management. 2 1 4 5 6 7 8 9 10 3 11 12 13 In the display window (caption 1) the values currently saved in the memory, taking the resonance selection key (caption 3) into account, are displayed.
The Program analysis (caption 6) orders the Rayocomp PS 1000 Polar to compare the values of the memory with those of the integrated programs. In this way, you can find out efficient programs for harmonizing.
User Manual Rayocomp PS 1000 Polar 38 Page 2- The function of the key Save as program (caption 7) allows drawing up of your own harmonizing programs. If you want to add an integrated program to the values in the memory, simply press the key: Load integrated program (caption 8). If you want to delete single values, add values or remove double values, the key Enter, delete interference value, ... (caption 9) has the corresponding function in store for you.
Page 2- User Manual Rayocomp PS 1000 Polar 39 2.6.2 How can I enter single interference values into the memory, delete single values, delete the complete contents of the memory or delete double values from the memory? Select the Bio-resonance according to Paul Schmidt in the main menu, then press the key Memory management and finally the key Enter, delete interference value, … before applying the required functions. The picture you can see on the right appears.
User Manual Rayocomp PS 1000 Polar Page 2-40 2.6.3 How can I analyse the values of the memory concerning the correlating indications? Select the Bio-resonance according to Paul Schmidt in the main menu, then press the key Memory management and finally the key Interference analysis before working with the required functions. The picture you can see on the right appears.
Page 2-41 User Manual Rayocomp PS 1000 Polar 2.6.4 How can I find out, which of the integrated programs has the highest compatibility with the values in the memory, in order to receive a suggestion for harmonising? Select the Bioresonance according to Paul Schmidt in the main menu, then press the key Memory management and finally the key Program analysis before working with the required functions. 1 The picture you can see on the right appears.
User Manual Rayocomp PS 1000 Polar Page 2-42 It takes the Rayocomp PS 1000 Polar approximately 30 seconds for the calculation. Finally, the results of the analysis can be seen in the display: The seven programs with the highest variances are displayed. Higher variance means more similarity between the program and the contents of the memory. The ideal case: the program has the same number of memory values, and all interferences are in accordance (then the variance is larger or equals 1000).
Page 2-43 User Manual Rayocomp PS 1000 Polar 2.6.5 How can I transform the contents of the memory into an own, permanently integrated program? With the Rayocomp PS 1000 Polar, you are able to store your own programs. Just like the 54 existing Rayonex programs, you can call them up with F1 and also use them for program analysis. An own program is drawn up by preparing the memory contents (enter, delete, add etc.) and storing these values, while giving an own program name at the same time.
User Manual Rayocomp PS 1000 Polar 2.6.6 Page 2-44 How can I add an integrated program to the memory contents? You can add single values as well as the values from the integrated programs to the memory contents. Here is a description of the last mentioned: You must select the Bioresonance according to Paul Schmidt in the main menu, then press the key Memory management and finally the key Load integrated program before you can work with the required functions.
Page 2-45 User Manual Rayocomp PS 1000 Polar 2.6.7 How can I add the values of an external memory card to the contents of the memory, and how can I delete a memory card and save the contents of the memory on the empty memory card? With the use of external memory cards, the Rayocomp PS 1000 Polar remains very flexible. For example, you can generate a harmonizing program for a patient, which he can use at home with a Rayocomp PS 100. Furthermore, the memory cards are excellent external memorys for programs.
Page 2-46 User Manual Rayocomp PS 1000 Polar 2.6.8 How can the values of the memory contents be printed? The Rayocomp PS 1000 Polar is set to a certain printer type by the manufacturer. If you prefer a different printer type, a Rayonex technician or the technical department of Rayonex can alter the setup. Select the Bio-resonance according to Paul Schmidt in the main menu, then press the key Memory management to perform the required functions. The picture you can see on the right appears.
User Manual Rayocomp PS 1000 Polar Page 2-47 2.7 Questions concerning the secondary menu point “Harmonize” The menu point Harmonization provides you with several harmonizing methods. For one, you can harmonize with the values of the memory, a further possibility is harmonizing with range values. Allergen desensitising is also possible with this menu point.
User Manual Rayocomp PS 1000 Polar 2.7.1 Page 2-48 How do I harmonize the interference values of the memory? With this function, the values in the memory can be harmonised. Select the Bio-resonance according to Paul Schmidt in the main menu, then press the key Harmonization and finally the key Harmonization with memory values before working with the required functions. The picture you can see on the right appears. Here you can pre-set certain details for harmonization.
User Manual Rayocomp PS 1000 Polar Page 2-49 2.7.2 How can I harmonize with the interferences of a certain range (with start value, final value and step length)? This function is very suitable for activating the physiological resonances. A certain range is pre-set, and with defined step lengths, the resonances are passed on to the patient.
User Manual Rayocomp PS 1000 Polar Page 2-50 2.7.3 How can I carry out an allergen desensitisation? The Rayocomp PS 1000 Polar supports allergen tests and desensitisation extraordinarily well. A protection cup can be found on the front left side of the Rayocomp, in which you can place the tested allergens in ampoules, without letting them get in touch with the oscillation pattern of other allergens or those of the patient, which would certainly falsify them.
User Manual Rayocomp PS 1000 Polar Page 2-51 2.8 Questions concerning the secondary menu point “Energetic duplication” 2.8.1 How can I carry out energetic duplication of substances? With the Rayocomp PS 1000 Polar, you can transfer the oscillation pattern of a substance to another carrier medium, i.e. Rayotabs. Please regard, that it is prohibited to produce an energetic duplicate and assign healing properties to this.
geopathy etc. Therefore, energised Rayotabs should be consumed within a period of 14 days.
User Manual Rayocomp PS 1000 Polar Page 3-1 3. The Module Bioenergetics according to Manfred Denecke – Questions The questions concerning this module relate to the key of the main menu marked with an arrow: Note: We would like to point out, that this module does not belong to the basic equipment delivered with the Rayocomp PS 1000 Polar. Of course, you can only call up this function, if the module is integrated in your device! Item 7.1.
User Manual Rayocomp PS 1000 Polar Page 3-2 3.
User Manual Rayocomp PS 1000 Polar Page 3-3 3.2 What are the conditions, or what kind of schooling is necessary, before I can apply Bioenergetics according to Manfred Denecke with my Rayocomp PS 1000 Polar? 1. Training courses: If the therapy program is supposed to be applied with success, special training courses are required beforehand.
User Manual Rayocomp PS 1000 Polar 3.3 Page 3-4 What are the functions made available for the Rayocomp PS 1000 Polar by the module Bioenergetics according to Manfred Denecke? If the module Bioenergetics according to Manfred Denecke is integrated in your Rayocomp PS 1000 Polar, you will see the following picture on your screen, as soon as you have pressed the key Bioenergetics according to Manfred Denecke in the main menu.
User Manual Rayocomp PS 1000 Polar Page 3-5 Caption 2: Bioenergetic Analysis Bioenergetic analysis in the Bioenergetics module according to Manfred Denecke is a compilation of the frequency compositions, which are most important to test. The test contains external disturbance factors, like E-smog or geopathy, as well as all the important tests on bacteria and viruses. Heavy metal pollution and further environmental factors can also be checked.
User Manual Rayocomp PS 1000 Polar Page 4-1 4. Questions concerning the Bio-Resonance according to Paul Schmidt - Veterinary Medicine The question concerning this module relates to the key of the main menu marked with an arrow: Note: We would like to point out, that this module does not belong to the basic equipment delivered with the Rayocomp PS 1000 Polar, it is not available in this program version yet. 4.
User Manual Rayocomp PS 1000 Polar Page 5-1 5. Harmony with Sounds of Nature and Music The questions in this chapter relate to the key of the main menu marked with an arrow: Note: We would like to point out, that this module does not belong to the basic equipment delivered with the Rayocomp PS 1000 Polar. Of course, you can only call up this function, if the module is integrated in your device! Item 7.1.4 informs you, how to look into the integrated modules in the Rayocomp PS 1000 Polar.
User Manual Rayocomp PS 1000 Polar Page 5-2 5.1 How can I play a single music title? After you have pressed the key Harmony with sounds of nature and music in the main menu, please activate the key marked with an arrow. Now you can take a look at the selection menu and select the desired music title with the help of the keys on the right. You can choose between 54 different music titles, each corresponding with a certain system range of the human being.
User Manual Rayocomp PS 1000 Polar Page 5-3 5.2 How can I play a series of music at random? After you have pressed the key Harmony with sounds of nature and music in the main menu, please activate the key marked with an arrow. The Rayocomp PS 1000 Polar has an exit for a hi-fi system at the back, so you can take the opportunity of playing classical music mixed with sounds of nature in your practice, for instance in the waiting room. This is a frequent request, and can be fulfilled with this function.
User Manual Rayocomp PS 1000 Polar Page 6-1 6. Patient administration – Questions The questions in this chapter relate to the key of the main menu marked with an arrow: Note: A patient administration with room for up to 10 patients belongs to the basic delivery volume of the Rayocomp PS 1000 polar. You can only administrate more patients, if the corresponding module is integrated in the device. Item 7.1.4 informs you, how to look into the integrated modules in the Rayocomp PS 1000 Polar.
User Manual Rayocomp PS 1000 Polar 6.1 Page 6-2 What are the advantages of the patient administration in the Rayocomp PS 1000 Polar? One of the outstanding new possibilities of the Rayocomp PS 1000 polar is the new patient administration. You can simply look into older sessions, analyse and repeat them, if this seems promising. The aim of the patient administration integrated in the Rayocomp PS 1000 Polar is to simplify the working cycles of the therapist.
User Manual Rayocomp PS 1000 Polar Page 6-3 6.2 How can I draw up a new patient in the patient administration of the Rayocomp PS 1000 Polar? After you have pressed the key Patient administration in the main menu, please activate the key marked with an arrow. Then, the following page is displayed. In order to draw up a new patient file, please press the key marked with an arrow.
Page 6-4 User Manual Rayocomp PS 1000 Polar The entry window for a new patient can now be seen on the screen. 1 2 3 The patient number is entered automatically. It consists of the month, the year and a continuous number, which is available only once. The key Alter behind this number (see caption 1) allows you to alter the patient number individually. Enter the gender by touching the little boxes or the text “male” or “female”.
User Manual Rayocomp PS 1000 Polar Page 6-5 6.3 How can I alter, i.e., the address of a patient in the Rayocomp PS 1000 Polar? After you have pressed the key Patient administration in the main menu, please activate the key marked with an arrow. Then, the following page is displayed. If you want to change the patient data, use the key marked with an arrow Alter patient data. The edit window will appear, showing the patient data previously entered.
Page 6-6 User Manual Rayocomp PS 1000 Polar 6.4 How can I determine the next patient for the session in the Rayocomp PS 1000 Polar? After you have pressed the key Patient administration in the main menu, please activate the key marked with an arrow.
User Manual Rayocomp PS 1000 Polar Page 6-7 6.5 The patient session has come to an end. How can I pass this on to the Rayocomp PS 1000 Polar? After you have pressed the key Patient administration in the main menu, please activate the key marked with an arrow. When the key is pressed, the name of the therapist will appear in the upper margin of your screen again, telling you that you are no longer in the patient history.
User Manual Rayocomp PS 1000 Polar Page 6-8 6.6 How can I look into previous test and harmonization sessions in the Rayocomp PS 1000 Polar and repeat them, if required? After you have pressed the key Patient administration in the main menu, please activate the key marked with an arrow. You will arrive directly in the patient history. If testing and harmonizing sessions have already been stored in the patient history, you have the chance to look at them now.
User Manual Rayocomp PS 1000 Polar Page 7-1 7.
User Manual Rayocomp PS 1000 Polar Page 7-2 7.1.1 How many hours have I already been using the Rayocomp PS 1000 Polar? After you have pressed the key System information and System setup in the main menu, please activate the key marked with an arrow. The total operation hours of the Rayocomp PS 1000 Polar as well as the operation hours since the last service are displayed in hours and minutes.
User Manual Rayocomp PS 1000 Polar Page 7-3 7.1.2 Next service – when is it due? After you have pressed the key System information and System setup in the main menu, please activate the key marked with an arrow. You will see the operation hours and the current service state. Service is due, as soon as the device indicates 100%. When service is due, the device will give you a message, as soon as it has been switched on. Then it is time to contact your Rayonex customer service department.
User Manual Rayocomp PS 1000 Polar Page 7-4 7.1.3 What is the program version and serial number of my Rayocomp PS 1000 Polar? After you have pressed the key System information and System setup in the main menu, please activate the key marked with an arrow. Now you can read the program version number and the series number of the Rayocomp PS 1000 Polar from the display.
User Manual Rayocomp PS 1000 Polar Page 7-5 7.1.4 What kind of program modules are integrated in my Rayocomp PS 1000 Polar? After you have pressed the key System information and System setup in the main menu, please activate the key marked with an arrow. Now you can see the program modules integrated in your Rayocomp PS 1000 Polar. A program module is a compilation of certain functions of the device. For example, the module acupuncture oscillation therapy can be integrated in your device.
User Manual Rayocomp PS 1000 Polar Page 7-6 7.1.5 What are the harmonizing programs integrated in my Rayocomp PS 1000 Polar? After you have pressed the key System information and System setup in the main menu, please activate the key marked with an arrow. Now you can see the therapy program modules integrated in your Rayocomp PS 1000 Polar. A therapy program module is a compilation of different single harmonizing programs.
User Manual Rayocomp PS 1000 Polar Page 7-7 7.1.7 How can I test the connection cables of the hand and foot detectors on their functioning order? If you are unsure, whether the connection cables of the detectors are in order, you can check their transmission and their functionality with this test. After you have pressed the key System information and System setup in the main menu, please activate the key marked with an arrow. You will see the following display.
User Manual Rayocomp PS 1000 Polar Page 7-8 Now insert the connection cables at the back of the device (see the following illustration). Press the key Cable test on the screen. After the test, the device gives you a message telling you, whether the cables inserted in the back are working or not.
User Manual Rayocomp PS 1000 Polar Page 7-9 7.2 System setup – Questions 7.2.1 How can I store the name of my practice in the Rayocomp PS 1000 Polar? You can enter a user’s name or the name of your practice, i.e. Practice Dr. Mustermann, in every Rayocomp PS 1000 Polar. This name appears in the upper margin of the screen (in the illustration: Practice Rayonex), as long as you have not selected a patient from the patient administration. With this function, you can personalise the device for your patients.
User Manual Rayocomp PS 1000 Polar Page 7-10 7.2.2 How can I provide read and write protection for my memory cards, delete them completely and gain information concerning a certain memory card? Although you can store your own harmonizing programs in the Rayocomp PS 1000 Polar, you can still use the memory cards. For this reason, the Rayocomp PS 1000 Polar also offers possibilities for calling up memory card information, read- or write-protecting memory cards or deleting the contents completely.
User Manual Rayocomp PS 1000 Polar Page 7-11 Memory cards - information Perhaps the sticker of the memory card has become illegible, then this function can help you to find out, how many interferences are stored on this card, whether the card is read- or write-protected and how many interferences can be stored on this card at all.
User Manual Rayocomp PS 1000 Polar Page 7-12 7.2.3 How can I alter the time and value setup of the Rayocomp PS 1000 Polar? If you want to use the Rayocomp PS 1000 Polar to harmonise, i.e. with the help of the integrated harmonizing programs, the device will suggest a pre-set harmonizing time. This time can be pre-set here. Further pre-settings are: step lengths for the range value test, refined step lengths, start and final values.
User Manual Rayocomp PS 1000 Polar Page 7-13 7.2.4 How can I enter my own interferences? Besides the given interferences from the manufacturer, you can also set your own interferences in the Rayocomp PS 1000 Polar and use them for testing or analysing, but also for harmonization. After you have pressed the key System information and System setup in the main menu, please activate the key marked with an arrow. Now you arrive in a navigation window (see chapter 1.4.
User Manual Rayocomp PS 1000 Polar Page 7-14 The picture, which appears now, allows you to enter the interference and its corresponding description. Check the entries, and if they are correct, they can be taken over with the key Take over entry. If you want to leave the entry window without storing first, please use the key Close.
User Manual Rayocomp PS 1000 Polar 7.2.5 Page 7-15 How can I alter the date and time in the Rayocomp PS 1000 Polar? Of greatest importance for the patient history is the correct entry of date and time. Only if the date is set correctly in the Rayocomp PS 1000 Polar can the device assign the performed examinations and harmonizations to the right date. After you have pressed the key System information and System setup in the main menu, please activate the key marked with an arrow.