Specifications
112 FT-857D Operating Manual
MENU MODE No•089
[
XVTR A FREQ
]
Function: Allows an arbitrary frequency to be set on the display, to allow direct frequency
readout during transverter operation; can also be used to account for frequency conversion
inaccuracies when a known reference frequency is known.
The setting procedure is as follows:
1. Press the MEM/VFO CH knob momentarily. You will see cursor flashing under at the
1st digit.
2. Rotate the MEM/VFO CH knob to move the cursor to the desired digit.
3. Rotate the DIAL knob to select what numeric value put on this digit.
4. Repeat step 2 and 3 as many times as necessary to complete the arbitrary frequency.
5. Press the MEM/VFO CH knob to save the new setting and exit.
Available Values: 00,000,00 ~ 99,999,99 (kHz)
Default: Current VFO frequency.
MENU MODE No•090
[
XVTR B FREQ
]
Function: Allows an arbitrary frequency to be set on the display, to allow direct frequency
readout during transverter operation; can also be used to account for frequency conversion
inaccuracies when a known reference frequency is known.
1. Press the MEM/VFO CH knob momentarily. You will see cursor flashing under at the
1st digit.
2. Rotate the MEM/VFO CH knob to move the cursor to the desired digit.
3. Rotate the DIAL knob to select what numeric value put on this digit.
4. Repeat step 2 and 3 as many times as necessary to complete the arbitrary frequency.
5. Press the MEM/VFO CH knob to save the new setting and exit.Available Values:
00,000,00 ~ 99,999,99 (kHz)
Default: Current VFO frequency.
MENU MODE No•091
[
XVTR SEL
]
Function: Enable/disable the Transverter function.
Available Values: OFF/X VTR A/X VTR B
Default: OFF
OFF: Disables the Transverter operation feature.
X VTR A: Activates the transverter operation feature. The display frequency may be set
via MENU No-089
[
XVTR A FREQ
]
.
X VTR B: Activates the second transverter operation display. The display frequency may
be set via No-090
[
XVTR B FREQ
]
.