User's Manual

Versus Technology, Inc.
24 Versus Information System
To install and wire sensors:
1. Referring to the floor plan schematic diagram, identify sensor locations and verify
identification numbers.
2. Create a hole for the sensor in ceiling tile or ceiling surface using a 2-3/8" hole saw.
3. Pull the sensor cable wire-pair through the hole and connect to the sensor using UY
splice connectors.
4. Gently bend the spring steel clips upward and insert the sensor into the ceiling tile hole.
The steel clips and the sensor cover will “sandwich” the ceiling tile and hold securely.
5. Mark the sensor as installed on the floor plan diagram or Punch-down Block Wire
Organization List.
4.3 Collector and Concentrator Installation
An example of neatly installed punch-down blocks, collectors, and concentrators.
The punch-down blocks, collectors, and concentrators should be installed in a secure location,
such as a communication or server room. The installation should allow for wiring access, neat
Concentrators
Punch-down
Blocks
Collectors
24V AC
Sensor wires