2. Mount the collector adjacent and connected to the associated punch-down block, using the
Velcro tape and clip provided with the unit. When using Velcro tape to secure a collector unit,
make sure the solid metal end clip is firmly secure to prevent sagging of the connection
between the collector and punch-down block.
4.4 Connecting Sensors to Collectors
Sensors are connected to the collectors through punch-down blocks. The punch-down block is
organized so that each two punch-down block rows, starting at the top left of the block, are one
collector port that is connected to by one sensor.
Bridge-clips are used to connect left-side pins to the right-side pins, which are wired to the collector
unit. If patching of sensor inputs is required, jumpers can be used from any sensor wire-pair on the left
to any collector wire-pair on the right.
Make sure power is not supplied when connecting components.
Punch-down Block