Plug the power supply connector into the concentrator and observed the red LED indicator lights. If it
fails to light, recheck the power and connections.
There are four LED indicator lights on the Concentrator. The function of each is described in the
diagram below.
Concentrator
The LED indicator light on the Collector will blink every time it receives badge data from the sensors.
If the LED blinks in a four or 5-blink pattern, this indicates that it is not communicating with the
concentrator. If this is the case, there is a problem with either the network cable connection or the
connection to the concentrator. If the LED blinks in a 3-blink pattern, this indicates a problem with the
collector, and it should be sent to Versus Technology for repair.
4.5.5.4 Walking Setup Test
After the Database Server, Badge Server and Configuration Utilities have been installed, you should
perform a walking setup of the system to verify sensor locations. The Ethernet Concentrator and
Database Server Manual describes the installation and configuration of the Badge Server and Database
Server. The Configuration Utilities Manual includes adding collectors, adding room locations,
matching up the sensors with locations, and testing them with the walking setup.
4.6 Testing RF Sensors
The Frequencer is utility that shows data being received by sensors. Data can be filtered to show only
information for a specific badge or sensor. The Frequencer is instrumental in testing that all areas of
the facility are covered by RF sensors.
To test RF sensor coverage:
1. Open the Frequencer, which is installed to the Versus\IRTools directory. The file is TCPFreq.exe.