3. Pull the sensor cable wire-pair through the hole and connect to the sensor using UY splice
connectors.
4. Gently bend the spring steel clips upward and insert the sensor into the ceiling tile hole. The
steel clips and the sensor cover will “sandwich” the ceiling tile and hold securely.
5. Mark the sensor as installed on the Installation Checklist.
4.3 Punch-down Block and Collector Installation
An example of neatly installed punch-down blocks, collectors, and concentrators.
The punch-down blocks, collectors, and concentrators should be installed in a secure location, such as
a communication or server room. The installation should allow for wiring access, neat wire routing
and dress, and connection of any sensor wire-pair to any collector input. Neat and orderly punch-
down blocks are easier to troubleshoot and maintain.
To install the punch-down blocks and collectors
Concentrators
Punch-down
Blocks
Collectors
24V AC
Sensor wires