Installation Manual

Versus Technology, Inc.
DT10000-A0001 28 Revision 8 December 1998
6. Mark the collector cable as checked on the Installation Checklist.
7. For each collector perform the following:
a) For the collectors identified on the contractual floor plan schematic diagram as LAST, set the
UNTERMINATED/TERMINATED switch to the TERMINATED position. For all other collectors,
set the switch to UNTERMINATED.
b) Insert the RJ plug(s) into the collector receptacle(s) (either collector receptacle is acceptable.)
c) Mark the collector as installed on the Installation Checklist.
Table 9-1. Collector RJ-12 Plug Wire Colors
Plug
Pin
No.
CAT 5 Wire
Color
Description Voltage
3 White/Blue Data (+) + 1 VDC
4 Blue Data (-) + 1 VDC
5 White/Orange Ground 0 VDC
6 Orange Ground 0 VDC
NOTE:
With connector pins pointing toward the installer, cable away from the installer, pin 1 is to the left.
See diagram below.
Pin 1
Top Tab