SG71090 24-Port 10/100/1000Base Modular Pick-a-Port Switch with Management & 100/1000Base SFP support Installation Guide v2.0 © January 2013 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com www.versitron.
PROPRIETARY DATA All data in this manual is proprietary and may not be disclosed, used or duplicated, for procurement or manufacturing purposes, without prior written permission by VERSITRON. VERSITRON LIFETIME WARRANTY All VERSITRON products are covered by a Lifetime Warranty against defects in materials and workmanship. This coverage is applicable to the original purchaser and is not transferable.
The information contained in this document is subject to change without prior notice. Copyright (C) All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. FCC NOTICE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including the interference that may cause undesired operation.
Table of Contents 1. Introduction......................................................................................................................................................5 1.1 Features ................................................................................................................................. 6 1.2 Product Panels....................................................................................................................... 8 1.3 Optional Modules ....................
1. Introduction The SG71090 24-port Switch is a standard L2 switch that meets all IEEE 802.3/u/x/z Gigabit, Fast Ethernet specifications. The switch provides three 8-port modular slots, each capable of accommodating one 8-port module. A variety of modules are available, including 10/100/1000M copper, 100/1000M fiber optic SFP, Copper and fiber optic SFP combination, and Fast Ethernet fiber optic modules. Different modules can be installed to create flexibility within your network.
1.
Management Features: z Port Control - Port Speed/Duplex Mode/Flow Control/Power saving configuration - Port frame size control (Jumbo frame support) z QoS - Traffic Classification up to 4 active priorities - Port QoS configuration - QoS Control List for policy rules - Port bandwidth control for ingress and egress - Storm Control for UC, MC and BC z Layer2 - Auto MAC address learning and ageing - Static MAC address filtering - Port-based and 802.
1.2 Product Panels The following figure illustrates the front panel and rear panel of the SG71090: Model Front Panel Rear Panel (Power Input) SG71090 SG71090-DC 1.3 Optional Modules Module Part No. Image Specifications SG71890 z 8 10/100/1000 copper ports z 8 RJ-45 jacks SG71896 z 8-port 100/1000 SFP slots z Supports standard 100M or 1000M fiber optic SFP modules www.versitron.
SG71896-44 z 4 10/100/1000 copper ports with RJ-45 connectors z 4 dual-speed SFP slots support standard 100M or 1000M fiber optic SFP modules SG71894 z 8 fixed 100M fiber ports SG71895 z 8 duplex SC connectors z Options: SG71894: MMF 2km SG71895: SMF 20km SG71894-26 z 6 fixed 100M fiber ports with 6 SG71895-26 duplex SC connectors z 2 10/100/1000 copper ports with RJ-45 connectors z Fiber options: SG71894-26: MMF 2km SG71895-26: SMF 20km SG71893 z 8 fixed 100M fiber ports z 8 duplex ST connec
SG71895-SFA z 8 fixed 100M fiber ports with SG71895-SFB SC connectors z Full-Duplex Bi-directional communication over a single-fiber z Options: SG71895-SFA: Tx: 1310nm, Rx: 1550nm SG71895-SFB: Tx: 1550nm, Rx: 1310nm z SMF 20km SG71895-26SFA z 6 fixed 100M fiber ports with SG71895-26SFB SC connectors z 2 10/100/1000 copper ports with RJ-45 connectors z Full-Duplex Bi-directional communication over a single-fiber z Options: SG71895-26SFA: Tx: 1310nm, Rx: 1550nm SG71895-26SFB: Tx: 1550nm, Rx: 1310n
1.3.1 Optional Module Table Module Part No. 10/100/1000M Copper ports SG71890 100/1000M pluggable SFP Fixed 100M Fiber 8 RJ-45 SG71896 8 SFP SG71896-44 4 RJ-45 4 SFP SG71893 8 ST for MMF 2km SG71894 8 SC for MMF 2km SG71895 8 SC for SMF 20km SG71895-SFA 8 Bi-Di SC SG71895-SFB for single SMF 20km SG71895-26 2 RJ-45 6 SC for SMF 20km SG71894-26 2 RJ-45 6 SC for MMF 2km SG71893-26 2 RJ-45 6 ST for MMF 2km SG71895-26SFA 2 RJ-45 6 Bi-Di SC SG71895-26SFB for single SMF 20km 1.
Dual-speed SFP Slots Compliance IEEE 802.3z 1000BASE-SX/LX (mini-GBIC) IEEE 802.3u 100BASE-FX Connectors SFP slot supports 100M and 1000M fiber optic SFP modules Configuration options Auto-negotiation 1000Mbps Full duplex Forced 100Mbps Full duplex (Software configurable) Network cables MMF 50/125μm 60/125μm, SMF 9/125μm Eye safety IEC 825 compliant Fixed 100M Fiber Ports Compliance IEEE 802.
QoS function Ethernet type, IP-based, DSCP, TOS-based, VID-based, VLAN Tag-based packet classification Port rate control, storm control Port Mirroring Mirror received frames to a sniffer port AC Power Input (SG71090) Interface IEC320 receptacle Operating Input Voltages 100 ~ 240VAC, 50/60Hz, 1.7A Power Consumption 40W max. DC Power Input (sg71090-DC Interfaces Screw-type terminal block Operating Input Voltages +40 ~ +72VDC Power Consumption 40W max.
2. Installation 2.1 Unpacking The product package contains: z SG71090 z One AC power cord (with SG71090) z One 19” rack mounting kit 2.2 Safety Precautions To reduce the risk of bodily injury, electrical shock, fire and damage to the product, observe the following precautions. z Do not service any product except as explained in your system documentation. z Opening or removing covers may expose you to electrical shock. z Only a trained service technician should service components inside the device.
2.3 Installing Modules The steps to install a module are as follows: 1. Unscrew the screws and remove the cover of the module slot. (Do not discard the screws.) 2. Insert the module into the slot until it is seated into the internal slot connector properly. 3. Push in the screw tabs and install the screws 4. Tighten the screws to secure the module to the switch chassis. www.versitron.
2.4 Removing the Modules The steps to remove an installed module are as follows: 1. Remove the screws securing the module to the switch chassis: 2. Slide out the screw tabs: 3. Use the screw tabs as handles to slide the module out from the internal slot connector: 4. Remove the module from the slot. www.versitron.
2.5 Mounting the SG71090 Desktop Mounting The SG71090 can be mounted on a desktop or shelf. Make sure that there is proper heat dissipation from and adequate ventilation around the device. Do not place heavy objects on the device. Rack Mounting Two 19-inch rack mounting brackets are supplied for 19-inch rack mounting. The steps to mount the SG71090 onto a 19-inch rack are: 1. Turn the power to the switch off. 2.
2. Mount the SG71090 securely onto 19-inch rack with rack screws (not provided): 3. Apply power to the switch. 2.6 Applying AC Power – SG71090 1. Connect the AC power cord to the SG71090 before plugging it into the AC power outlet. 2. Connect the SC power cord to the AC power outlet. SG71090 AC Power Connector AC power input specifications Connector: IEC320 type Power Rating: 100 ~ 240VAC, 50/60Hz Voltage Range: 90 ~ 264VAC Frequency: 47 ~ 63 Hz Power Consumption: 40W max. www.versitron.
2.7 Applying DC Power – SG71090-DC The SG71090-DC power connector is shown below: SG71090-DC Power Connector DC power input specifications Receptacle: Screw-type terminal block Operating Voltages: +40 ~ +72VDC Power Consumption: 40W max. Contacts VDC+ input VDC- input Ground www.versitron.
2.8 Reset Button The reset button is used to perform a reset of the switch. It can be used for diagnostic purpose or if the network performance has an issue. The button can also be used to restore the software configuration settings to factory default values. The operations are as follows: Operation Function Press the button during system boot-up and release Restore factory default settings it after boot-up. The boot-up takes about 17 seconds and ends with LED diagnostics.
Auto-negotiation Function The ports are featured with auto-negotiation function and full capability to support connection to any Ethernet devices. The port performs a negotiation process for the speed and duplex configuration with the connected device automatically each time a link is being established. If the connected device is also auto-negotiation capable, both devices will configure to the best performance option after negotiation process.
3. Push the module into the slot until it is seated securely in the slot and then place the bail in lock position. Connecting Fiber Cables LC connectors are commonly equipped on most SFP. Identify the TX and RX connector before making the cable connection. Plug in the cables as shown below. Make sure the RX-to-TX connection rule is followed between two ends of the connected cable. 2.
Identify the TX and RX connector before making the cable connection. Plug in the cables as shown below. Make sure the RX-to-TX connection rule is followed between two ends of the connected cable. 2.12 Making Fixed Bi-Di (Bi-Directional) Fiber Connections The following figure illustrates an example of fixed Bi-Di (Bi-directional) fiber port with one SC connector. www.versitron.
A Bi-Di port supports single fiber connection. It uses different optical wavelengths for transmitting and receiving data as shown below: www.versitron.
2.13 LED Indications LED Function Color State Interpretation POWER Power status Green ON The power is supplied to the switch. OFF Mngt Management status Green OFF 1000M The switch is initialized completely with diagnostic error. ON The switch is initialized completely and normal. Port speed status Green ON Port link status www.versitron.com The switch is in initialization and diagnostics. BLINK OFF Link/Act. The power is not supplied to the switch.
2.14 Making Console Connection The console port is a DB9 connector. It serves as an RS-232 DTE port.
3. Managing the Switch The SG71090 provides the following methods to configure and monitor the switch: z Making out of band management via RS-232 console port z Making in-band management via telnet interface over TCP/IP network z Making in-band management via web interface over TCP/IP network z Making in-band SNMP management over TCP/IP network 3.1 IP Address & Password The IP Address is an identification of the switch in a TCP/IP network.
Enter the following default values in the login page: Fixed User Name: admin Default password: No password is required. Click OK to login into the switch. The following page is displayed after a successful login: Select [Configuration] -> [Security] -> [Switch] -> [Password] to configure a new password www.versitron.
Password configuration web page Configuration Description Old Password Enter the current system password. If this is incorrect, the new password will not be set. New Password New system password to be used The allowed string length is 0 to 31, and the allowed content is the ASCII characters from 32 to 126. Confirm New Password Save Re-enter the new system password. Click to save the changes. Select [Configuration] -> [System] -> [IP & Time] to configure IP address IP Configuration web page www.
Configuration Description DHCP Client Enable the DHCP client by checking this box. IP Address Provide the IP address of this switch unit. IP Mask Provide the IP mask of this switch unit. IP Router Provide the IP address of the default router for this switch unit. VLAN ID Provide the managed VLAN ID. The allowed range is 1 through 4095. SNTP Server Provide the IP address of the SNTP Server. Save Click to save the changes.
3.4 Reference Manuals for Web, Console, Telnet Management The following operation manuals are also provided separately for Console, Telnet and Web management: • SG71090 - Telnet & Console Management Manual • SG71090 – Web –Based Management Manual The manuals describe the detailed commands and information. 3.5 Configuration for SNMP Management The switch supports SNMP v1, SNMP v2c, and SNMP v3 management.
>SNMP Community Delete >SNMP Community Lookup [] >SNMP User Add [MD5|SHA] [] [DES] [] >SNMP User Delete >SNMP User Changekey [] >SNMP User Lookup [] >SNMP Group Add >SNMP Group Delete >SNMP Group Lookup [] >SNMP View Add [included|excluded] >SNMP View Delete >SNMP View Lookup [
3.6 SNMP MIBs The switch provides the following SNMP MIBs: - RFC 1213 MIB II - RFC 3635 Ethernet-like MIB - RFC 4188 Bridge MIB - RFC 3636 802.3 Medium Attachment Units (MAUs) MIB - RFC 2863 Interface Group MIB using SMI v2 - RFC 4133 Entity MIB v3 - RFC 2933 IGMP MIB - IEEE 802.3AB LLDP MIB One product MIB file is also available in the product CD for SNMP manager software. www.versitron.
Appendix A – Duplex Fiber Modules Model Speed (Mbps) Wavelength Media Distance FEMM 100 850nm MMF 2km LC FE2MM 100 1310nm MMF 2km FE10SM 100 1310nm SMF GBMM 1000 850nm GB2MM 1000 1310nm GB10SM 1000 1310nm GB20SM 1000 1310nm SMF GB40SM 1000 1550nm GB70SM 1000 GB100SM 1000 www.versitron.com RX Sens Temp -10 ~ -4 < -24 0 to 70° C LC -20 ~ -4 < -31 0 to 70° C 10km LC -15 ~ -8 < -34 0 to 70° C MMF 220m(62.5µ) / 550m(50µ) LC -9.
Appendix A – Single Fiber Modules Model Speed (Mbps) GB10SFA 1000 Wavelength Media Distance Connector TX Power RX Sens Temp SMF 10km LC -3 ~ -9 < -21 0 to 70° C SMF 10km LC -3 ~ -9 < -21 0 to 70° C SMF 20km LC -3 ~ -8 < -23 0 to 70° C SMF 20km LC -3 ~ -8 < -23 0 to 70° C SMF 40km LC -3 ~ +2 < -23 0 to 70° C SMF 40km LC -3 ~ +2 < -23 0 to 70° C SMF 60km LC 0 ~ +5 < -24 0 to 70° C SMF 60km LC -2 ~ +4 < -25 0 to 70° C SMF 80km LC -2 ~ +3 < -26 0 to