Setup Guide

2.
Sensor Disassembly
Insert a screwdriver or thumbnail in the slot at
the bottom of sensor (1) to push inward on cover
latch. Remove cover (2). At the right side of the
sensor base (3), push outward on circuit board
latch. Using the circuit board battery holder as
handle, gently lift circuit board right side and
remove.
3. Base Hole Preparation
Identify necessary holes on diagram;
1) For wall mounting, knock out hole covers.
2) For corner or 45 degree wall mounting,
use a drill to open at least two holes at
base side depressions.
4. Wall Mounting
Use screws to mount on wall or in a corner.
5. Strips Installation
Install the three adhesive strips (3M).
6. Circuit Board and Battery Installation
To replace circuit board:
1) Insert circuit board
right edge into two left-
hand mounting slots in
sensor base.
2) On right-hand side, gently press
circuit
board into place until latch snaps over
circuit board.
3) Insert the CR123 battery in the battery holder.
Be
sure that the (+) is in the correct position
.
7. Operation Programming
Use High-Sensitivity if there is a way for
intruders to pass only a very short distance in
the sensor's view, or if aggressive detection
is required. Otherwise, normal sensitivity is
fine for ordinary applications. Factory-set
positions are shown below in gray.
NOTE: LED turn on is for test only. Continual
LED use will shorten battery life.
OE-PIR433 Motion
Sensitivity J4
1-3 2-1
Normal High
Frequency S3 ON OFF
8. Motion Distance Sensitivity
Set J4 (Sensitivity setting) according to need.
Normal sensitivity - detection occurs in 3 to 5
steps.
High sensitivity - detection occurs in 2 to 4 steps.
9. Operation Programming
The table below provides possible LED
indications.
0E-PIR433 Motion
Sensor State LED Display
Warm-up OFF
Alarm ON (2 seconds)
Normal OFF
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the
equipment unless authorized by the Installation Instructions or
User Manual. Unauthorized changes or modifications could void the
user's authority to operate the equipment
FCC/IC STATEMENT
This device complies with Part 15 of the FCC Rules, and Industry
Canada’s license-exempt RSSs. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference (2) This device must accept any interference
received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC et
exempt de licence RSS d’Industrie Canada. Son
fonctionnement est soumis aux conditions suivantes: (1) Cet appareil
ne doit pas causer d' interférences nuisibles. (2) Cet
appareil doit accepter toute interférence reçue y compris les
interférences causant une réception indésirable.
The product should not be disposed of with other household waste.
Check for the nearest authorized collection centers or authorized
recyclers. The correct disposal of end-of-life equipment will help
prevent potential negative consequences for the environment and
human health.
Specifications
IR Sensor: .................................................................................................................................. Dual Elements
Optical Fields-of-View ......................................................... Long-Range 44', Mid-Range 36', Short-Range 18'
Events Detection: ........................................................................... High Bar™ false alarm rejection processor
Sensitivity: .................................................................................... Selectable: 2-event or 3-eventPower Supply
Range: ............................................ 40' in sensor-facing direction, 40' at 45° angle from sensor-facing direction
Power Supply: .................................................................................................................... CR123A 3V Battery
Power Supply Current: ............................................................................................................. 22uA (no alarm)
RF Immunity: ................................................................................................ 20 V/m, 10-1,000MHz. 1 V/m, 1-2
White Light Immunity: .......................................................................................................................... 6,500 lux
Tamper Switch: ................................................................................................................ Sealed dome-contact
Operating Temperature: ............................................................................................................. -40˚C to +50˚C
Pet Immunity: .............................................................................................................................................. 60lb
Housing Material: ................................................................................................................... High-impact ABS
Dimensions: .......................................................................................................... 2.9" x 2.4" x 1.7" (H x W x D
Support & Warranty
For technical support please call 833 574-9124
For warranty information please go to: www.adiglobal.com
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE
CONTROL WITH WHICH THIS DEVICE IS USED FOR DETAILS
REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
The HighBar
trademark is used by permission.
All
®
trademarks are the property of their respective owners
R800-27522A 4/22 Rev A
ADI Global Distribution
275 Broadhollow Road
Melville, NY 11747
www.adiglobal.com