Product Card
Table Of Contents
- Cloud Services Gateway 300 Series
- At a Glance
- CSG300 Appliance Models
- Chassis Views
- CSG300 Series Appliance Specifications
- Chassis Specifications
- CSG300 Series Appliance SKUs
- Regulatory Compliance
- Certifications
- Export Control Information
- Front and Rear Panel Components
- Front Panel
- Rear Panel
- Additional Information
- Network Interface Card Modules
- LTE Modem Module
- Embedded WiFi Module
- Interface Numbering
- Power Supply and Airflow
- AC Power Supply
- Airflow Requirements
- Installation Guidelines
- General Safety Guidelines
- Federal Communication Commission Interference Statement
- Prepare the Site for Installation
- Site Preparation Guidelines
- Environmental Requirements
- Rack Requirements
- Airflow Requirements
- Install a CSG300 Series Appliance
- Unpack a CSG300 Series Appliance
- Packing List for a CSG300 Series Appliance
- Mount a CSG355 or CSG365 Appliance in a Rack
- Connect a CSG300 Series Appliance
- Step 1: Connect Earth Ground to a CSG300 Series Appliance
- Step 2: Connect AC Power to a CSG300 Series Appliance
- Step 3: Configure a Management Console to Connect to a CSG300 Series Appliance
- Step 4: Connect a CSG300 Series Appliance to a Management Console
to issuing the shutdown now command from the operating system shell.
• If you press and hold the button for 10 seconds or more, the power for the appliance turns off and the appliance
shuts down.
Reset Button
The Reset button on the rear panel of a CSG300 series appliance resets the appliance. The reset functionality depends
on the number of times you press the button within a span of 30 seconds, as described in Table 3.
The Reset button is recessed so that it is not accidentally pressed while the appliance is operational.
To press the Reset button, use a sharp, narrow tool.
Table 3: Reset Button Press Behavior
Number
of Presses Behavior
2 Reset the appliance to the factory-default snapshot.
4 Reset the appliance to the branch prestaging configuration.
6 Reset the appliance to the branch staging configuration.
8 Reset the appliance to branch post-staging configuration.
You can reset the appliance to the factory-default configuration by issuing the request system reset CLI command.
Reset the Appliance to the Factory-Default Configuration from the CLI
You can reset the appliance to the factory-default configuration from the CLI. You can connect to the appliance through
the serial console port or by using SSH.
The factory default reset procedure may take up to 20 minutes to complete. Do not power off the appliance during this
time.
To reset an appliance to the factory default configuration:
1. To connect to the appliance through the serial console port, see Configure a Management Console to Connect to a
CSG300 Series Appliance.
2. Log in to the appliance CLI using the username "admin" and the password "versa123".
Note: To connect to the appliance using SSH, connect your PC to the management port of the appliance. For the
port mapping on the CSG700 series appliance, see Interface Numbering. The management port has the default
static IP address 10.10.10.10/24. Configure the PC IP address to any IP from this segment, for example,
10.10.10.1/24. Open an SSH session to the appliance using its IP address, 10.10.10.10.
https://docs.versa-networks.com/Versa_Internal/WIP/Antony/Cloud_Services_Gateway_300_Series
Updated: Tue, 01 Dec 2020 03:50:36 GMT
Copyright © 2020, Versa Networks, Inc.
12