Cloud Services Gateway 300 Series At a Glance The Versa Cloud Services Gateway (CSG) 300 series appliances deliver highly secure site-to-site data connectivity to small businesses and to home offices. These appliances provide the following features: • Support for different CPUs and memory sizes: • Management Ethernet ports with dual use and dedicated options: ◦ One RJ45 RS-232 console port ◦ One USB 2.
Table 1 shows the CPU memory, and storage sizes of the CSG300 appliance models . Table 1: CSG300 Appliance Models CSG Appliance Model CPU Memory Storage CSG350 x86 with 4 cores 4 GB DRAM (configurable to 16GB) 32 GB CSG355 x86 with 4 cores 8 GB DRAM 32 GB CSG365 x86 with 4 cores (higher performance) 8 GB DRAM 64 GB Chassis Views The CSG350 appliance is the smallest of the CSG300 appliances. The CSG355 and CSG365 appliances are physically identical.
CSG355 and CSG365 Appliances Figure 3 and Figure 4 show the front and rear panels of the CSG355. The panels for the CSG355 and CSG365 appliances are identical. Figure 3: Front Panel of the CSG355 Appliance Figure 4: Rear Panel of the CSG355 Appliance CSG300 Series Appliance Specifications A CSG300 series appliance chassis is made of aluminum for optimal heat dissipation. This article lists the chassis and regulatory compliance specifications for the CSG300 series appliance.
Chassis Specifications CSG350 Appliance Table 1 lists the specifications for a CSG350 appliance chassis. Table 1: CSG350 Series Chassis Specifications Item Specification Services and Slot Density RJ-45 ports 10/100/1000 Mbps 4 External USB ports (USB 2.
Item Specification Package width 16.7" (42.4 cm) Package depth 12" (30.48 cm) Package weight 15.
Item Specification Services and Slot Density RJ-45 ports 10/100/1000 Mbps 4+2 External USB ports (USB 2.0) 1 RJ-45 serial console port 1 Memory DDR4 ECC DRAM CSG355: 8 GB CSG365: 8 GB Disk 1 SSD default size CSG355: 32 GB CSG365: 64 GB Power supply Processor 12VDC, 5A High-performance, 4-core processor Power Specifications AC input voltage 100–240 Volts AC input line frequency 50–60 Hz Typical power consumption 33 Watts Chassis Physical Specifications Chassis height 1.
Package weight 15.
yyy indicates the type and number of NIC ports. It can be one of the following: • 4GP—4 general-purpose NIC ports • 8GP—8 general-purpose NIC ports • T1/E1—1 T1/E1 NIC port • xDSL—1 VDSL NIC port Regulatory Compliance Table 3 lists the regulatory compliance specifications for a CSG300 series chassis. Table 3: CSG300 Series Regulatory Compliance Specifications Item Specification Safety CE Marketing Security TPM 2.
Region Certifications • FCC 47 CFR Part 15C, 15.247 (Bluetooth) • MPE • Contain FCC ID: N7NEM7455 • Contain FCC ID: 2ARF9CSG-W1 Export Control Information Table 5 lists the ECCN, HTS, and CCATS numbers.
LED Color Power Green Status • Off: Appliance is not powered on. • Green: Appliance is powered on. • Off: Appliance hardware is up, but there is a problem with the software. • Solid green: Appliance is up and running. Status Green, Red • Blinking green: Appliance is in the process of booting up. • Red: Major error condition exists in the system or there is a corrupt software configuration. • Blinking red: System crash, overheating, or a persistent error condition exists.
LED Color Power Green Status • Off: Appliance is not powered on. • Green: Appliance is powered on. • Off: Appliance hardware is up, but there is a problem with the software. • Solid green: Appliance is up and running. Status Green, Red • Blinking green: Appliance is in the process of booting up. • Red: Major error condition exists in the system or there is a corrupt software configuration. • Blinking red: System crash, overheating, or a persistent error condition exists.
to issuing the shutdown now command from the operating system shell. • If you press and hold the button for 10 seconds or more, the power for the appliance turns off and the appliance shuts down. Reset Button The Reset button on the rear panel of a CSG300 series appliance resets the appliance. The reset functionality depends on the number of times you press the button within a span of 30 seconds, as described in Table 3.
3. Issue the following commands to reset the configuration to factory default. If the current software version on the appliance is the same as that of the factory reset snapshot, the procedure takes about 10 minutes to complete. If the software versions are different, the procedure takes about 20 minutes to complete. Do not power off the appliance during the process. % cli % request system reset 4. Verify that all Versa services are running by issuing the vsh status command from the Linux bash CLI.
Network Interface Card Modules The CSG355 and CSG365 appliances offer field configurability using the network interface card (NIC) slot. See Table 1. Table 1: CSG355 and CSG365 NIC Card Support Name Description NIC 1VA 1-port A/VDSL Annex A NIC NIC 1VB 1-port A/VDSL Annex B NIC NIC 4DS 4-port T1/E1 NIC NIC 4GP 4-port copper PoE/PoE+ NIC The CSG355 and CSG365 appliances offer interface modularity, providing four Ethernet ports that support both Type 1 and Type 2 PoE devices.
Figure 3 shows the CSG350 series appliance VNI port mapping. Figure 3: CSG350 RJ-45 Connectors for 1-GB Copper GE Combination Port LTE Modem Module The CSG300 series LTE modem module is a high-performance Cat-6 LTE Advanced (LTE-A) modem that provides download speeds up to 300 Mbps and upload speeds up to 50 Mbps. The LTE modem supports multiple carriers, and it has been certified by major global carriers. The appliance has two externally accessible SIM card slots, one for each embedded LTE-A modem.
• Global navigation satellite system (GNSS) receiver enables tracking and location-based services. • Stores up to three firmware versions, thereby allowing the modem to switch to other networks. • Firmware can be upgraded over the air. • Secure boot provides secure connectivity by preventing unauthorized code on target devices. The LTE modem connections are metered connections, and the Versa software implementation ensures that the LTE service is charged only when needed.
labeled SIM1 and SIM2. Note: If the appliance has two SIM card slots, use SIM slot 1 and vni-0/100 port for bootstrapping when you upgrade the software to a later version. If the appliance is powered off when you insert the SIM card or cards, the LTE functionality is activated when you boot the appliance. If you insert the SIM card or cards into the LTE modem module when the appliance is powered on and operational, you must reboot the appliance to restart the LTE modem and LTE functionality.
Interface Numbering Figure 1 shows the mapping of the Ethernet ports to virtual network interface (VNI) numbering for the CSG350 appliance. Figure 1: CSG350 Port-to-VNI Mapping Figure 2 shows port-to-VNI mapping for the CSG355 and CSG365 appliances. Note that the CSG355 and CSG365 chassis are identical. Figure 2: CSG355 and CSG365 Port-to-VNI Mapping Power Supply and Airflow This article describes the AC power supply and airflow requirements for CSG300 appliances. https://docs.versa-networks.
AC Power Supply By default, CSG300 series appliances ship with one AC power supply unit. If you order the CSG300 series appliance with the power-over-Ethernet (PoE) NIC module, an additional power supply unit ships with the appliance. Table 1 describes the AC power supply specifications for each power supply unit.
around your bare wrist, making good skin contact. Failure to use an ESD grounding strap could damage the appliance. • Install the CSG300 series appliance in compliance with the following local, national, and international electrical codes: • United States—National Fire Protection Association (NFPA 70), United States National Electrical Code. • Other countries—International Electromechanical Commission (IEC) 60364, Part 1 through Part 7. • Evaluated to the TN power system.
This equipment complies with CE and FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. Warning: Operation of this equipment in a residential environment could cause radio interference. Warning: Operation of this equipment is for indoor use only.
admissible maximal. Les types d'antenne non inclus dans cette liste, et dont le gain est supérieur au gain maximal indiqué pour tout type figurant sur la liste, sont strictement interdits pour l'exploitation de l'émetteur. • LTE EM7455 modules—Radio émetteur IC:2417C-EM7455 ◦ Gain d'antenne: 3.23 dBi maximal ◦ Type d'antenne: 50 ohm, Dipole • WiFi CSG-W1 modules—Radio émetteur IC:26338-CSGW1 ◦ Gain d'antenne: 4.
Environmental Requirements • Ensure that the area in which you operate the appliance has adequate air circulation so that the cooling system functions normally. Ambient air temperature may not be sufficient to cool the chassis to acceptable operating temperatures without adequate circulation. • Avoid temperature extremes. • High humidity conditions can cause moisture to penetrate into the chassis. The appliance can operate in relative humidity of 10% to 85%, non-condensing.
Unpack a CSG300 Series Appliance The CSG300 series appliance is packed in a plastic box, and it is shipped in a cardboard carton, secured with foam packing material. The carton also contains an accessory box. It is recommended that you unpack the appliance only when you are ready to install it. To unpack a CSG300 series appliance: 1. Open the top flaps of the cardboard carton. 2. Remove from the box the foam packing material holding the appliance and the accessories in place. See Figure 1. 3.
Note: It is recommended that you save the shipping carton and packing material when unpacking the appliance, in case you need to later move the appliance or return it. See How To Return Hardware. Packing List for a CSG300 Series Appliance The cardboard carton in which a CSG300 series appliance is shipped contains a packing list. Check the packing list against the parts that you receive in the shipping carton. https://docs.versa-networks.
Packing List for the CSG350 Appliance Table 1 lists the parts shipped with a CSG350 appliance. Table 1: Parts Shipped with a CSG350 Appliance Components Quantity CSG350 appliance chassis 1 AC power adapter 1 Power cable (US only) 1 LTE antenna (included with LTE module only) 2 for single LTE module 4 for dual LTE module Packing List for the CSG355 or CSG365 Appliance Table 2 lists the parts shipped with a CSG355 or CSG365 appliance.
To mount the appliance, ensure that you have the following tools: • Number 2 Phillips (+) screwdriver • Tape measure To mount a CSG355 or CSG365 appliance in a four-post 19-inch rack: 1. Place the appliance chassis on a flat, stable surface. 2. Check the internal dimensions of the rack with a tape measure. The appliance is 22 cm wide (about 8.6 inches) and must fit within the mounting posts. 3. Allow a minimum of 0.5 RU space above the appliance for airflow, to allow hot air to flow out.
5. Grasp both sides of the appliance chassis, making sure that the front of the chassis is facing you. 6. Stand in front of the rack and lift the chassis. Then, gently insert the chassis into the rack and slide it as far back as possible. Figure 4: Insert a CSG365 Series Appliance into the Rack 7. Have the second person secure the mounting ears to the front of the rack using the rack-mount screws that are shipped with the appliance. Insert and then tighten the screws.
Connect a CSG300 Series Appliance This article describes how to connect a CSG300 series appliance to an AC power source and to a management console. Step 1: Connect Earth Ground to a CSG300 Series Appliance To ensure proper operation of a CSG300 series appliance and to meet safety and electromagnetic interference (EMI) requirements, you must connect the appliance to earth ground before you connect power to the appliance. The CSG300 series appliance requires a three-prong power cable.
• Electrostatic discharge (ESD) wrist strap. • AC power cord shipped with the appliance. The cord has plugs appropriate for your geographical location. To connect a CSG300 series appliance to an AC power source: 1. Attach one end of the ESD grounding strap to your bare wrist, and connect the other end to the ESD point on the rack. 2. Plug one end of the AC power cord into the power supply in the appliance. 3. Plug the other end of the AC power cord into an AC power source outlet. 4.
2. In the Category navigation pane, click Session, and then in the Connection Type menu, click Serial. https://docs.versa-networks.com/Versa_Internal/WIP/Antony/Cloud_Services_Gateway_300_Series Updated: Tue, 01 Dec 2020 03:50:36 GMT Copyright © 2020, Versa Networks, Inc.
3. In the Category navigation pane, click Connection > Serial. The Options Controlling Local Serial Lines page displays. https://docs.versa-networks.com/Versa_Internal/WIP/Antony/Cloud_Services_Gateway_300_Series Updated: Tue, 01 Dec 2020 03:50:36 GMT Copyright © 2020, Versa Networks, Inc.
4. In the Serial Line To Connect To field, enter the COM port that your device is connected to. The default COM port is COM1. https://docs.versa-networks.com/Versa_Internal/WIP/Antony/Cloud_Services_Gateway_300_Series Updated: Tue, 01 Dec 2020 03:50:36 GMT Copyright © 2020, Versa Networks, Inc.
5. In the Configure the Serial Line section, enter the following information. https://docs.versa-networks.com/Versa_Internal/WIP/Antony/Cloud_Services_Gateway_300_Series Updated: Tue, 01 Dec 2020 03:50:36 GMT Copyright © 2020, Versa Networks, Inc.
a. In the Speed (Baud) field, enter the digital transmission speed. For CSG700 series appliances, the speed must be 115200. b. In the Data bits field, enter the number of data bits used for each character. The recommended value is 8. c. In the Stop bits field, enter the number of bits to be sent at the end of every character. The recommended value is 1. d. In the Parity field, select None. This is the method of detecting errors in transmission. e. In the Flow Control field, select None.
7. Click Save. 8. To open the session, click Open. https://docs.versa-networks.com/Versa_Internal/WIP/Antony/Cloud_Services_Gateway_300_Series Updated: Tue, 01 Dec 2020 03:50:36 GMT Copyright © 2020, Versa Networks, Inc.
9. Log in to the appliance CLI with the username "admin" and the password "versa123". https://docs.versa-networks.com/Versa_Internal/WIP/Antony/Cloud_Services_Gateway_300_Series Updated: Tue, 01 Dec 2020 03:50:36 GMT Copyright © 2020, Versa Networks, Inc.
Step 4: Connect a CSG300 Series Appliance to a Management Console You can configure and manage a CSG300 series appliance using a management console. Use a cable with an RJ-45 connector to connect the CSG300 series appliance to the management console. To connect a CSG300 series appliance to a management console: 1. Plug one end of the console cable into the console port located on the rear panel of the CSG300 series appliance. 2.