Symptom: Potential Cause(s): Recommendation(s):
Pump Cycles Once
Deadhead(systempressuremeetsorexceedsair
supply pressure).
Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroow.
(Doesnotapplytohighpressure2:1units).
Air valve or intermediate gaskets installed incorrectly. Installgasketswithholesproperlyaligned.
Bent or missing actuator plunger. Remove pilot valve and inspect actuator plungers.
Pump Will Not Operate
/ Cycle
Pumpisoverlubricated. Setlubricatoronlowestpossiblesettingorremove.Unitsaredesignedforlubefreeoperation.
Lackofair(linesize,PSI,CFM). Checktheairlinesizeandlength,compressorcapacity(HPvs.cfmrequired).
Check air distribution system. Disassembleandinspectmainairdistributionvalve,pilotvalveandpilotvalveactuators.
Dischargelineisblockedorcloggedmanifolds. Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.
Deadhead(systempressuremeetsorexceedsair
supply pressure).
Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroow.
(Doesnotapplytohighpressure2:1units).
Blockedairexhaustmufer. Removemuferscreen,cleanorde-ice,andre-install.
Pumpeduidinairexhaustmufer. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.
Pumpchamberisblocked. Disassembleandinspectwettedchambers.Removeorushanyobstructions.
Pump Cycles and Will
Not Prime or No Flow
Cavitation on suction side. Check suction condition (move pump closer to product).
Check valve obstructed. Valve ball(s) not seating
properly or sticking.
Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket.
Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged.
Use heavier valve ball material.
Valve ball(s) missing (pushed into chamber or
manifold).
Wornvalveballorvalveseat.Wornngersinvalveballcage(replacepart).CheckChemical
Resistance Guide for compatibility.
Valve ball(s)/seat(s) damaged or attacked by product. Check Chemical Resistance Guide for compatibility.
Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.
Suction line is blocked. Removeorushobstruction.Checkandclearallsuctionscreensorstrainers.
Excessivesuctionlift. Forliftsexceeding20’ofliquid,llingthechamberswithliquidwillprimethepumpinmostcases.
Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.
Pumpeduidinairexhaustmufer. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.
Pump Cycles Running
Sluggish/Stalling,
Flow Unsatisfactory
Over lubrication. Setlubricatoronlowestpossiblesettingorremove.Unitsaredesignedforlubefreeoperation.
Icing. Removemuferscreen,de-ice,andre-install.Installapointofuseairdrier.
Clogged manifolds. Cleanmanifoldstoallowproperairow
Deadhead(systempressuremeetsorexceedsair
supply pressure).
Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroow.
(Doesnotapplytohighpressure2:1units).
Cavitation on suction side. Check suction (move pump closer to product).
Lackofair(linesize,PSI,CFM). Checktheairlinesize,length,compressorcapacity.
Excessivesuctionlift. Forliftsexceeding20’ofliquid,llingthechamberswithliquidwillprimethepumpinmostcases.
Airsupplypressureorvolumeexceedssystemhd. Decreaseinletair(press.andvol.)tothepump.Pumpiscavitatingtheuidbyfastcycling.
Undersizedsuctionline. Meetorexceedpumpconnections.
Restrictiveorundersizedairline. Install a larger air line and connection.
Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.
Suction line is blocked. Removeorushobstruction.Checkandclearallsuctionscreensorstrainers.
Pumpeduidinairexhaustmufer. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.
Check valve obstructed. Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket.
Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.
Entrainedairorvaporlockinchamber(s). Purgechambersthroughtappedchamberventplugs.Purgingthechambersofaircanbedangerous.
Product Leaking
Through Exhaust
Diaphragmfailure,ordiaphragmplatesloose. Replace diaphragms, check for damage and ensure diaphragm plates are tight.
Diaphragmstretchedaroundcenterholeorboltholes. Checkforexcessiveinletpressureorairpressure.ConsultChemicalResistanceChartforcompatibility
withproducts,cleaners,temperaturelimitationsandlubrication.
Premature Diaphragm
Failure
Cavitation. Enlargepipediameteronsuctionsideofpump.
Excessiveoodedsuctionpressure. Movepumpclosertoproduct.Raisepump/placepumpontopoftanktoreduceinletpressure.
Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.
Misapplication(chemical/physicalincompatibility). ConsultChemicalResistanceChartforcompatibilitywithproducts,cleaners,temperaturelimitations
and lubrication.
Incorrectdiaphragmplatesorplatesonbackwards,
installedincorrectlyorworn.
CheckOperatingManualtocheckforcorrectpartandinstallation.Ensureouterplateshavenotbeen
worntoasharpedge.
Unbalanced Cycling
Excessivesuctionlift. Forliftsexceeding20’ofliquid,llingthechamberswithliquidwillprimethepumpinmostcases.
Undersizedsuctionline. Meetorexceedpumpconnections.
Pumpeduidinairexhaustmufer. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.
Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.
Check valve obstructed. Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket.
Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.
Entrainedairorvaporlockinchamber(s). Purgechambersthroughtappedchamberventplugs.
For additional troubleshooting tips contact After Sales Support at service.warrenrupp@idexcorp.com or 419-524-8388