Installation Instructions
77
20" 7/16
(519 mm)
13" 7/64
(332.9 mm)
2" 11/32
(59.5 mm)
minimum
7” 7/8
(200 mm)
=
=
=
=
minimum
19" 19/64
(490 mm)
cut-out height
26" 25/32
(680 mm)
minimum height
from the oor
14" 7/8
(378 mm)
cut-out width
28” 1/2
(724 mm)
minimum
cut-out
depth
23" 1/2
(597 mm)
1
Fig. 1.2
Fig. 1.3
Fig. 1.4
Provide hole
for electrical
connection in
this area
Area for
electrical
connection
Provide a
hole for gas
connection to
1/2” diameter
pipe fitting
Gas line opening:
Provide a suitable hole on the bottom of
cutout. The centre of hole shall be 13”
7/64 (332.9 mm) from the centre of cutout
to the right side and 20” 7/16 (519 mm)
from the front corner of cutout to the back.
Grounded outlet:
The electric cord with 3-prong ground plug
has a length of 48” (1220 mm). Grounded
outlet should be located in an area 7” 7/8
(200 mm) below the bottom of cutout and
only on the left side of the cabinet.
A suitable hole has to be provided on the
bottom of the cutout, in an area positioned
on the left rear corner (2” 11/32 [59.5 mm]
maximum from the left side of cutout to
the centre and minimum 19” 19/64 [490
mm] from the front corner of cutout to the
back), to pass the appliance cable.
OVEN VENT