Installation Instructions

1212
1
2
NATURAL GAS
REGULATION
LP/PROPANE
REGULATION
A
Fig. 2.6
2
5. Leak Testing:
IMPORTANT: Leak testing of the appliance shall be conducted as follows:
After nal gas connection is made, turn on manual gas valve and test all connections in gas supply
piping and appliance for gas leaks with a soapy water solution. During this test all appliance gas
valves have to be closed.
In order to avoid property damage or serious personal injury, never use a Iighted match. If a leak is
present, tighten joint or unscrew, apply more joint compound, tighten again and retest connection for
leak.
CONVERSION TO LP/PROPANE GAS (OR CONVERSION BACK TO THE
ORIGINAL GAS - NATURAL GAS)
Every oven is provided with a set of injectors for the various types of gas.
Select the injectors to be replaced according to the “INJECTORS TABLE”.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.
CAUTION: Save the orices removed from the appliance for future use.
SETTING THE PRESSURE REGULATOR
1. Unscrew the regulator cover.
2. Unscrew the A” component, reverse and screw it according to the LP/PROPANE (or NATURAL GAS)
regulation.
INJECTORS TABLE
NOMINAL
POWER
REDUCED
POWER
LP/PROPANE
11” W.C.P.
NATURAL GAS
4” W.C.P.
BURNERS BTU/hr BTU/hr
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Oven burner 13500 2400 109 180
Broil burner 10000 - 95 155