Installation Guide
8
Gas supply line
Shutoff valve
“open” position
To oven
2
gasconnection
2.PressureRegulator:
a. Allheavyduty,commercialtypecookingequipmentmusthaveapressureregulator
ontheincomingservicelineforsafeandefcientoperation,sinceservicepressure
mayuctuatewithlocaldemand.
Beforeinstallingtheregulatormountthe3/8”NPT(conical)maleconnectortothe
regulator(seepicture2.2).
Gasketsuppliedhastobeplacedbetween3/8”NPT(conical)connector/manifold
malepipefitting(seepicture2.3).
Theregulatorsuppliedwiththisovenmustbeinstalledbeforeanygasconnections
aremade.
Usesuppliedpressureregulatoronly.
Explosion Hazard
Use a new CSA or UL approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas connec-
tions.
If connected to LP, have a quali-
fied person make sure gas pres-
sure does not exceed 14" water
column.
Examples of a qualified person
include licensed heating per-
sonnel, authorized gas compa-
ny personnel, and authorized
service personnel.
Failure to do so can result in
death, explosion, or fire.
Fig. 2.1
Allgasconnectionsmustbemadeaccordingtonationalandlocalcodes.Thisgassupply
(service)linemustbethesamesizeorgreaterthantheinletlineoftheappliance.Sealant
onallpipejointsmustberesistanttotheactionofLP/Propanegas.
The oven is equipped for the use with NATURAL gas. It is design-certied by CSA
InternationalforNATURALandL.P.gaseswithappropriateconversion.
The model/serial rating plate, located on the back of the oven, has information on
the type of gas that can be used. If this information does not agree with the type of
gasavailable,checkwiththe local gas supplier.Seepagefrom12 to 15 for L.P.gas
conversioninstructions.
1.ManualShut-offValve(g:2.1):
Amanualshut-offvalvemustbeinstalledinanaccessiblelocationinthegaslineexternal
totheapplianceforthepurposeofturningonorshuttingoffgas to the appliance (In
MassachusettssuchshutoffdevicesshouldbeapprovedbytheBoardofStateExaminers
ofPlumbers&GasFitters).
Thisvalveshouldbelocatedinthesameroomastheovenandshouldbeinalocation
thatallowseaseofopeningandclosing(inapositionwhereitcanbereachedquicklyin
theeventofanemergency).
Donotblockaccesstotheshutoffvalve.Thevalveisforturningonorshuttingoffgas
totheappliance.