Datasheet
19
Anschlußbelegung Connector pinning
PIN Funktion
VP80-1 VP80-1R VP80-2 VP80-3 VP80-4 VP150-1 VP150-1R VP150-3
A+B C+E D A+B C+D
4 +V1 +V1 — +V1 +V1 +V1 +V1 +V2 +V1 +V1 +5V
6 +V1 +V1 — +V1 +V1 +V1 +V1 +V2 +V1 +V1 +5V
8 Gnd V1 Gnd V1 — Gnd V1 Gnd V1 Gnd V1 Gnd Gnd Gnd V1 Gnd V1 Gnd V1
10 Gnd V1 Gnd V1 — Gnd V1 Gnd V1 Gnd V1 Gnd Gnd Gnd V1 Gnd V1 Gnd V1
12 +Sense +Sense — +Sense — +Sense +Sense +V1 +Sense +Sense +Sense
14 -SENSE -Sense — -Sense — -Sense -Sense — -Sense -Sense -Sense
16 PF/ DC-Fail/ — PF/ — PF/ PF/ PF/ Ext.on/off+ Ext.on/off+ PF/
18 — — +V1 — — +V2 +V2 +V3 — DC-Fail +12V
20 — ASF Gnd V1/V2 +V2 +V2 Gnd V2/V3 Gnd Gnd — ASF GND2
22 — — -V2 Gnd V2 Gnd V2 -V3 -V3 -V4 PF/ Vadj. –12V
24 — — — — — — — — Ext.on/off– Ext.on/off – Ext.on/off+
26 — — — — — — — — — — —
28 N N N N N N N N N N N
30 L L L L L L L L L L L
32 PE PE PE PE PE PE PE PE PE PE PE
H15-Stecker
Connector
VP80 and VP150 Series Mechanical Details, Connector Pinning
VP80 und VP150 Serien Mechanische Details, Steckerbelegung
Anmerkung: Die Sense-Leitungen müssen angeschlossen werden. Wegen der
maximalen Kompensation des Spannungsabfalls im Zuleitungskabel sollten sie
so nahe wie möglich an der Last angeschlossen sein.
Attention: The sense lines must be connected. For maximum compensation of
the voltage drops on the power cables they should be connected as close as
possible to the load.
www.eplax.de · www.eplax.co.uk
100
VP 80
3,27
32,91
160
7TE
VP 80
3HE = 128,5mm
Option EMV Frontplatte
Optional EMI frontpanel
Standard
Frontplatte
8TE
Basisgerät ohne Frontplatte
Basic unit without frontpanel
Gerät mit Standard Frontplatte
Unit with standard frontpanel
162mm
100mm
110mm
3HE = 128,5mm
12TE
60,6mm
VP 150
VP 80
VP 150
40,64
8,35