Problems and solutions
Flames
Condensation on the glass, right after lighting the fireplace
This is normal when the fireplace is still cold or cooled down. After a few seconds
the condensation disappears.
The flames in the middle are higher than the ones on the sides
Spread the stones again, if necessary put lesser stones.
There has been some time between installing and lighting the fireplace for the first time :
Because of the humidity and dust, the wholes in the burner may be blocked.
Clean the appliance with a vacuumcleaner. Open the wholes with a pointed object,
e.g. a small nail. Devide the stones equally over the burner and bottom of the
combustion chamber.
The appliance does not burn clean and the flames are too high
There has been ordered an appliance for natural gas, but you are using propane :
The burner can only be replaced by our technician. Contact your fitter.
Position “high flames” only gives small flames
There has been ordered an appliance for propane, but you are using natural gas :
The burner can only be replaced by our technician. Contact your fitter.
The flames do not respond when changing the position high/low
Keep pressing button 3 or 4 on the remote control during 15 seconds. The gasvalve
in the appliance will now react and adapt the gaspressure in the burner.
The appliance burns, but extinguishes suddenly without any reason
For some reason, a safety has interrupted the gas supply. Trace the cause of it :
is there enough fresh air, is the vent free?
After the pilot flame has extinguished, you have to wait for 5 minutes before you
can restart the fireplace.