Installation instructions Operating instructions G A L A GALA® Closed fireplace for natural gas propane Instal.
Installation instructions Operating instructions G A L A Summary Introduction …………………………………………………………………………………. 2 Caution ……………………………….……………………………………………….….. 4 Certificates ………………………………………….………………………………………… 5 …………………………….…………………………………………………….. 6 Components Gastechnical instructions Technical data GALA® ……………………………….…………………………………….. ……………….…………………………………….………………… Summary of delivered material Air flow 9 - 12 ………………………………………………….….………… 13 ………………….………………………………………………….…………….
Installation instructions Operating instructions Introduction G A L A Congratulations with your new GALA® gas fireplace. We selected the best materials to produce our fireplaces. This way you can enjoy your appliance for many years. Before using the GALA, please read this manual. CERTIFICATE OF CONFORMITY VERO DESIGN nv Koralenhoeve 3, Industriepark Noord – 2160 Wommelgem - Belgium herewith declares that GALA® is produced in accordance with European Security Regulations 90 / 396 EEG.
Installation instructions Operating instructions CAUTION ! G A L A Installation must be performed by a licensed plumber or gas fitter. Installation must comply with manufacturer’s installation instructions and national and regional instructions. If you have any doubts, consult your local energy provider. Before installation, determine if the information on the CE label matches the type of gas and gaspressure for your region.
Installation instructions Operating instructions Certificate Instal.
Installation instructions Operating instructions Components G A L A Components Appliance GALA Gasbed Certificate number E1530 Product identificaton PIN 0063BM1630 Gas block BM 740/3 modulerating Transfo IR (IRT)230Vac-24Vac Sensor IR receiver (IRR) Modubox MF-301C modubox Category I 2E+,I 2H,I 2L,I 2ELL,I 3+,I 3p Gas line pressure G20/20 – G25/25 The fireplace is equipped with the following safeties : Atmospheric safety : on the pilot flame TTB : in connection piece to chimney Cold
Installation instructions Operating instructions Gastechnical instructions G A L A DE – Deutschland Nationale Einbauvorschriften: DVGW-TRGI 86 / 96, technische Regel, Arbeitsblatt G600 bzw TRF Feu VO der jeweiligen Länderfassung AT – Österreich Nationale Einbauvorschriften: ÖVGW – Richtlinien G1 Gas, G2 Flüssiggas BE – Belgien Nationale inbouwvoorschriften: NBN D51 – 003 Gas , AREI/RGIE electrititeit CH – Schweiz Nationale Einbauvorschriften: SVGW-Gasleitsätze G1 Erdgas, EKAS-Richtlinie 1942 Flüssigg
Installation instructions Operating instructions Gastechnical instructions Gas Country appliance category Natural gas Propane AT:Österreich AT:Österreich BE: Belgien BE: Belgien CH: Schweiz CH: Schweiz DE: Deutschland DE: Deutschland LUX: Luxemburg LUX: Luxemburg NO: Norway NO: Norway AT/CH: I2H Natural gas H I3P Propane G31 BE: I2E+ Nat.gas G20 / G25 I3P Propane G31 DE: I2ELL Nat.
Installation instructions Operating instructions G A L A Technical data code A (mm) D (mm) O (mm) Gas Ø (mm) Kg consumtion m³/h natural gas Gas °C kW GALA 1F 800 130 150 15 mm ~120 0.85 155°C 5.0 – 11.0 GALA 2F 900 130 150 15 mm ~130 1.00 180°C 5.0 – 13.0 GALA 3F 1000 130 150 18 mm ~140 1.15 210°C 6.5 – 15.6 GALA 4F 1250 130 150 18 mm ~160 1.40 223°C 6.5 – 17.0 GALA 5F 1500 150 200 22 mm ~170 1.70 292°C 7.0 – 17.
Installation instructions Operating instructions G A L A Technical data see-thru / tunnel A (mm) D (mm) O (mm) Gas Ø (mm) Kg verbuik m³/h aardgas Gas °C kW GALA 1D 800 130 150 15 mm ~120 0.85 155°C 5.0 – 11.0 GALA 2D 900 130 150 15 mm ~130 1.00 180°C 5.0 – 13.0 GALA 3D 1000 130 150 18 mm ~140 1.15 210°C 6.5 – 15.6 GALA 4D 1250 130 150 18 mm ~160 1.40 223°C 6.5 – 17.0 GALA 5D 1500 150 200 22 mm ~170 1.70 292°C 7.0 – 17.
Installation instructions Operating instructions G A L A Technical data square code A (mm) D (mm) O (mm) Gas Ø (mm) Kg Gas m³/h °C kW GALA 70 F 700 130 150 15 ~110 0.73 220°C 5.0 – 11.0 GALA 80 F 800 130 150 15 ~125 0.80 230°C 5.0 – 13.0 GALA 90 F 900 130 150 18 ~140 0.85 238°C 6.5 – 15.6 Instal.
Installation instructions Operating instructions G A L A Technical data square tunnel code A (mm) D (mm) O (mm) Gas Ø (mm) Kg Gas m³/h °C kW GALA 70 D 700 130 150 15 ~110 0.73 220°C 5.0 – 11.0 GALA 80 D 800 130 150 15 ~125 0.80 230°C 5.0 – 13.0 GALA 90 D 900 130 150 18 ~140 0.85 238°C 6.5 – 15.6 Instal.
Installation instructions Operating instructions G A L A Delivered material Before you unpack the fireplace, check packaging for damages. In case of damage, contact us at +32/33.85.06.91. If possible send a picture of the damage to : info@verodesign.
Installation instructions Operating instructions Air flow G A L A Combustion air Fresh air, combustion air, primary air, has to be brought into the unit. This is possible from a different place under the unit or via a tube from an outside wall. Supply the unit with combustion air from underneath, do not connect. The air will find ist way into the burner by several openings. Convection air system When the convection air system is not wanted, close the openings on the unit with insulation material.
Installation instructions Operating instructions ! G A L A Preparations GALA has to be connected to an existing or new flue. GALA® IS NOT CONNECTED CONCENTRIC : The appliance draws combustion air from outside. Before installation, be sure that your flue is suitable for the ordered appliance. The flue ends outside. Have your flue swept by a certified chimney-sweeper ! Flue - situation 1 Flue - situation 2 Instal.
Installation instructions Operating instructions G A L A Preparing airflow Before installation: with or without airflow GALA® is equiped with 2 (1 x right + 1 x left) cold air entrances and 2 (1 x right + 1 x left) warm air outlets. If you connect the airflow system, there will be a better, natural circulation of the warm air in the room where the fireplace will be installed. There is no fan used. The perforation has already been done. Turn the perforated piece until it loosens.
Installation instructions Operating instructions G A L A Preparations GALA® Install the fireplace on a flat surface. Installation conform local fire safety instructions! By using the adjustable feet, you can level the fireplace. Flue - vertical termination : Install the fireplace underneath, centered the flue and in the center of the fresh air supply. Socket on the right, max. 100 cm from the fireplace. Gas line, in recommended Ø on the right of the appliance. Connect gas hose to gasline. (1, pag. 15).
Installation instructions Operating instructions G A L A Gas connection Flue – Horizontal termination : Install the appliance so that only one 45° elbow is used. Socket on the right side (see pag. 14) of the appliance, gas line on the right side of the fireplace and shut off with terminal safety device (1) (see example underneath). Connect and test !!! Put the plug in the socket, put gas hose (2) in therminal safety device (1) 1 and turn until you see a green arrow.
Installation instructions Operating instructions G A L A Checking the gaslines Purge the air from the gaslines. Check for gas leaks by using a qualified gas tester. GALA® - Only light the appliance when all lines are closed ! GALA® - Cover the burner and the bottom of the combustion chamber with the delivered stones. They are part of the entire CE approval of the appliance. Put max. 2 layers of pebbles and keep the rest seperately.
Installation instructions Operating instructions Lighting the fireplace G A L A When first operated, the appliance may release an odor. This is caused by the curing of the paint. This is a normal result. Ventilate the room properly ! ONLY LIGHT THE FIREPLACE WHEN GLASS IS INSTALLED GALA® The fireplace is controlled with a FULL-OPTION infra red remote control. The remote has a reach of ~4.00m. FULL-OPTION means : The appliance is lid from the OFF position of the pilot flame.
Installation instructions Operating instructions ! G A L A Installation General When the fireplace will be build in in a tiled stove, follow the installation instructions of the relating manufacturer ! When the fireplace will be build in in a brick wall or other, you must use heat-resistant insulation ! DO NOT PLACE ANY FLAMMABLE MATERIAL ON THE INSIDE OF THE CHIMNEY-PIECE ! By using insulation, the heat spreads more controlled : Through the glass and if wanted, also through the warm air vents, with
Installation instructions Operating instructions G A L A Insulation Insulation : all blue marked areas. To avoid unwanted heat transfer to materials in the vicinity of the fireplace, the appliance must be insulated with heat-resistant insulation : • both sides left / right • backside • top • connenction pieces to flue We recommend Promaglaf – HTK 1260°C or equivalent (see previous page) The repercusion safety on the backside of the flue connection needs to remain free. Instal.
Installation instructions Operating instructions Installation using convection system G A L A Step 1 + 2 Step 1 Installation : Pull up the brickwork, walls, until the bottom of the cold air connection piece • along the sides, keep away 10 mm from the frame • along the bottom, keep away 10 mm from the frame Step 2 Connect the cold air grilles to the connection pieces (150 mm) with a flexible tube. Instal.
Installation instructions Operating instructions Installation using convection system G A L A Step 3 + 4 Step 3 Put insulation on connection pieces. Step 4 Place the air grilles according to the manufacturer’s instructions. Pull up the brickwork until 10 mm from the top of the frame. Instal.
Installation instructions Operating instructions G A L A Installation using convection system Step 5 + 6 Step 5 / Detail page 26 Place a beam across. Keep a distance from 10 mm from the top of the frame. Step 6 Pull up the brickwork so that the flexibles for the warm air can be connected fluently with a 90° elbow. Instal.
Installation instructions Operating instructions Installation using convection system G A L A Step 7 + 8 Step 7 Place the warm air grilles and connect with aluflex. Step 8 Insulate the warm air connections. Instal.
Installation instructions Operating instructions G A L A Installation using convection system Step 9 Step 9 Close the walls and let dry. • The appliance is placed against a wall and on the floor according local fire safety regulations. • GALA is covered completely with insulation : except for the repercusion safety on the back. • The interspace on the front remains open. • Brickwork until 10 mm from the appliance. Profile Instal.
Installation instructions Operating instructions G A L A Installation not using convection system The appliance has to be covered with insulation (all blue marked areas), including the connection pieces for the air. The repercusion safety on the back of the fireplace remains free. Build in the appliance as mentionned on the previous pages, with exception of the grilles. After GALA has been build in, you can’t ingnite the appliance immediately.
Installation instructions Operating instructions Installation step 5 : detailled G A L A Brickwork on the 4 sides upto 10 mm from the frame. Instal.
Installation instructions Operating instructions Installation stucco - step 1 G A L A Place an L-profile, upto 3 mm from the appliance. Stucco the brickwork / wall. By using an L-profile you obtain an exact shadowjoint. Instal.
Installation instructions Operating instructions Installation stucco – step 2 G A L A Stucco brickwork / wall. By using an L-profile you obtain an exact shadowjoint. Instal.
Installation instructions Operating instructions G A L A Electronic schedule You find all electronic parts in the “technical box”. The box is situated in the middle on the bottom of the combustion chamber of the appliance. Remove the glass (see page 16) and the stones. Open the lid of the technical box.
Installation instructions Operating instructions G A L A Problems and solutions Flames The first person to contact is your professional dealer. LED 1 LED-indication on the remote control does not light up when lighting Replace batteries ( 2 x 1.5V, AAA, LR03) B-6 B-1 B- 5 B-2 B- 4 B-3 The remote control does not respond Replace batteries ( 2 x 1.5V, AAA, LR03). The receiver does not registrate the signal : move closer to the appliance and point at the opening in the middle of the lower frame.
Installation instructions Operating instructions G A L A Problems and solutions Flames Condensation on the glass, right after lighting the fireplace This is normal when the fireplace is still cold or cooled down. After a few seconds the condensation disappears. The flames in the middle are higher than the ones on the sides Spread the stones again, if necessary put lesser stones.
Installation instructions Operating instructions G A L A Problems and solutions General After the appliance is lit, there’s an odor coming from the appliance When first operated, the appliance may release an odor. This is caused by the curing of the paint. This is a normal result! Ventilate the room thoroughly. The air grilles (on top) draw air The grilles, warm / cold air, are not connected to the fireplace.
Installation instructions Operating instructions Problems and solutions General G A L A The paint is showing some damage You can order special VERO DESIGN paint spray at your professional dealer shop. This way you can repaint the damaged parts. The appliance does not heat sufficiently There has not been used enough insulation. The convection system has not been connected. Contact your professional dealer. Instal.
Installation instructions Operating instructions G A L A Maintenance Open the fireplace when it’s cold : Combustion area : Only dust with a duster. Do not use a moist or wet cloth, this may cause corrosion! If necessary, you can clean the back of the fireplace with a steel brush, dust it and repaint the back with special VERO DESIGN paint. Ignition pin : Gently and very carefully you must clean the ignition pin with the finest sandpaper once a year. All the dust and corrosion will be removed.
Installation instructions Operating instructions G A L A Warranty 2 Vero Design NV wishes to thank you for your trust and guarantees you that the fireplace GALA gas is made with utmost care and manufactured with the best materials. The warranty includes all production errors and the functioning of the appliance over a period of 2 years starting from the date of installation. You will find the warranty card on the last page of this manual.
Installation instructions Operating instructions Accessories G A L A MF-310 C Modubox Gas valve GB-055 Infra-red remote control Infra-red receiver Cables Instal.
Installation instructions Operating instructions Accessories G A L A Paint spray - colour 930 4 adjustable feet Decoration white – Carrara marmer Decoration grey Decoration ceramic wood Instal.