Operating instructions

20300293
5
Resolution Direct Vent Gas Fireplace

This appliance has been certied for use with either
natural or propane gas. See appropriate data plates.
This appliance is not for use with solid fuels.
The appliance is approved for bedroom or bedsitting
room installations.
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
This appliance is mobile home approved.
The appliance must be properly connected to a venting
system.
The appliance is not approved for closet or recessed
installations.
FP2594
VHLDV controls
Command Center
Figure 1 -
VHLDV Fireplace Controls
Gas Valve
Control Box
Access Panel
FP2594


Input ratings are shown in BTU per hour and are certied
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
Natural Propane (LP)
Inlet Minimum 4.5” w.c. 11.0” w.c.
Inlet Maximum 10.5” w.c. 13.0” w.c.
Manifold Pressure 3.5” w.c. 10.0” w.c.

   
VHLDV500 Nat. 2.3 mm #30 (.1285)
VHLDV500 LP #50 (.070") #55 (.052")


  
    
  
VHLDV500NTSC Nat. 50,000 35,500 17,500
VHLDV500PTSC LP 50,000 38,500 17,500