Operating instructions

18 20300293
Resolution Direct Vent Gas Fireplace
If the foundation
is recessed, use
recess brackets
(not supplied) for
securing lower
portion of the
snorkel. Fasten
brackets to wall
rst, then secure
to snorkel with
self drilling #8 x
1/2 sheet metal
screws. It will
be necessary to
extend vent pipes
out as far as the
protruding wall
face. Figure 19

FP1966
snorkel
Figure 19 -
Snorkel Installation, Recessed Foundation
Foundation
Recess
Watertight Seal
Around Pipe
Sheet Metal
Screws
Wall Screws
Snorkel

 
 


FP1183
max height
40' Maximum Height
12' Minimum Height
10'
Maximum
Support Straps
Every 3'
24" Min.
FP1183
Figure 21 -
Support Straps for Horizontal Runs
Vertical sections of this vent system require a minimum of
1" clearance to combustibles on all sides of the pipe.
Up to two 45° elbows may be used within the horizontal
run. For each 45° elbow used on the horizontal plane,
the maximum horizontal length must be reduced by 18"
(450 mm).
Example: Maximum horizontal length
No elbows = 10’ (3 m)
1x45° elbows = 8.5’ (2.6 m)
2x45° elbows = 7’ (2.1 m)
A minimum of an 8' (2.5 m) vertical rise is required.
Two sets of 45°elbows offsets may be used within the
vertical sections. From 0 to a maximum of 8' (2.5 m)
of vent pipe can be used between elbows. Figure 22
The maximum angular variation allowed in the system
is 270°. Figure 22
For the minimum height of the vent above the highest
point of penetration through the roof refer to Page 20,
Figure 26.


Install restrictor disc as shown in Figure 21 for vertically
vented applications.
Up to two (2) restrictor discs may be needed for 40' instal-
lation.
The two (2) restrictor discs suppled will work for most instal-
lations. If a third disc is needed order Part No. 56D3027.
This gas replace has been approved for,
Vertical installations up to 40' (12 m) in height. Up to
a 10' (3 m) horizontal vent run can be installed within
the vent system using a maximum of two 90° elbows.
Figure 21
 Horizontal sections of this vent system require a
minimum of 3" clearances to combustibles at the top of
the ue and 1" clearance at the sides and bottom until the
ue penetrates the outside wall. A minimum 1" clearance
all around the ue is acceptable at this point of penetration.
Unless the vertical run is 7Z\x feet or higher from oor of
replace, the clearance for the horizontal run is 1" on all
sides.

 
   

FP2706
FP2706
restrictor disc
Restrictor Disc
Fireplace Collar
Figure 20 -
Install Restrictor Disc
into Fireplace Collar