Consult local building codes before beginning the
installation. The installer must make sure to select the
proper vent system for installation. Before installing vent
kit, the installer must read this replace manual and vent
kit instructions.
Only a qualied installer/service person should install vent-
ing system. The installer must follow these safety rules:
• Wear gloves and safety glasses for protection.
• Use extreme caution when using ladders or when
on rooftops.
• Be aware of electrical wiring locations in walls and
ceilings.
The following actions will void the warranty on your vent-
ing system:
• Installation of any damaged venting component.
• Unauthorized modication of the venting system.
• Installation of any component part not manufactured
or approved by Vermont Castings Group.
• Installation other than permitted by these instruc-
tions.
* A minimum of 3" clearance to the top is
required along horizontal length until ue pipe
penetrates outside wall.
** A minimum 1" clearance to combustibles
permitted all around ue at outside wall
*3”
**1”
**1”
73”
(1854 mm)
FP2596
venting clearance
24" Vertical Rise
Required Before
Horizontal Run
Figure 7 -
Combustible
Clearances for Vent
Pipe
FP2596
until the ue penetrates the outside wall.