It may be necessary to adjust the burners periodically, to com-
pensate for variables in gas characteristics. If you notice the 
burner ame pattern is irregular (Refer to Page 14, Figures 9a, 
9b & 9c), it may be necessary to adjust the air shutter opening 
at the front of the venturi tubes. 
• 
The shutters are accessible under the control panel at the 
front of the Grill. (Fig. 19)
• 
Use a screwdriver to loosen the locking screws. Open the 
shutter just enough to achieve the desired soft, blue ames. 
Make adjustments in small increments and allow the burner 
to come up to operating temperature (10 min.) before mak-
ing further adjustments.
Always allow sufcient time for the Grill to cool to a safe tem-
perature before handling or cleaning any of its components.
If burners are removed for cleaning or adjustment, always  
conrm that they have been reinstalled correctly over the 
valve outlets. (Fig. 20) The valves should extend into the 
burner venturis 1/4” minimum.
Similar  adjustment  can  be  made  to  Rotisserie  and/or 
Side Burners, if so equipped.
"
ADJUSTAIRSHUTTER
Loosen the 
Locking Screw
Turn Shutter 
Clockwise to Open
B139
Figure 19
"
6ENTURIAIRSHUTTER
1/4” Minimum
B140
Figure 20
Valve Outlet