Specifications

TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
46
Blocked Flue Switch RFSDV34 (Procedure 35)
If the log fire has been recently operated the flue will be extremely hot. A
serious and significant burn hazard exists. Ensure the log fire is not
operating and that the flue has sufficiently cooled before attempting to
remove the blocked flue switch.
1. Remove two screws retaining blocked flue switch cover to draught diverter and
withdraw blocked flue switch cover and blocked flue switch from draught diverter.
2. Disconnect wiring to the blocked flue switch.
3. Complete reassembly in reverse order of above.
Cord Set RFSDV34 (Procedure 36)
1. Remove transformer (refer to procedure 33).
2. Mark and disconnect cord set wiring to the transformer.
3. Remove earth stud nut and remove cord set earth wire from earth stud.
4. Cut and remove cable tie retaining cord set compression gland.
5. Withdraw compression gland and cord set wiring through aperture in transformer
supporting bracket.
6. Remove compression gland from cord set wiring.
7. Complete reassembly in reverse order of above replacing cut cable tie.