Specifications

TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
43
Pilot Injector RFSDV34 (Procedure 25)
1. Isolate power and gas supplies to the log fire.
2. Remove glass frame assembly (refer to procedure 19).
3. Remove log assembly and larva rock from burner (reverse procedure 20).
4. Unscrew and remove top section of pilot light (section above bracket) from pilot
assembly.
5. Remove injector from top section of pilot light.
6. Complete reassembly in reverse order of above.
7. Test for gas leaks at all unions using soapy water solution.
Pilot Feed Pipe RFSDV34 (Procedure 26)
1. Remove pilot assembly (refer to procedure 22).
2. Unscrew pilot feed pipe nut at pilot light and remove pilot feed pipe from gas valve.
3. Complete reassembly in reverse order of above.
Burner RFSDV34 (Procedure 27)
1. Isolate power and gas supplies to the log fire.
2. Remove glass frame assembly (refer to procedure 19).
3. Remove log assembly and larva rock from burner (reverse procedure 20).
4. Remove two screws retaining log ember grill to log fire base and remove log ember
grill.
5. Remove two screws retaining burner hold down brackets to burner base brackets.
6. Remove screw retaining pilot heat shield to pilot assembly and remove pilot heat
shield.
7. Withdraw burner by lifting burner up at right hand side to clear pilot assembly and then
sliding towards pilot assembly. Note: burner injectors may catch on burner hindering
withdrawal and necessitating some jiggling of burner to remove.
8. Complete reassembly in reverse order of above.
9. Test for gas leaks at all unions using soapy water solution.
Burner Injectors RFSDV34 (Procedure 28)
1. Remove burner (refer to procedure 27).
2. Unscrew and remove front and/or rear burner injector(s).
3. Complete reassembly in reverse order of above using gas sealing paste on burner
injector threads.