Specifications
TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A 
D.O.I: 17/01/2008 
This document is stored and maintained electronically by   Service. All printed copies not bearing this statement in RED are deemed “uncontrolled” 
4 
Specifications 
Specification 
LHEC30 
RFSDV34 
Power supply 
240 VAC 50Hz 
Electrical connection 
10A 3 pin plug 
Gas input – NG 
32 MJ/hr 
Gas input – P 
32 MJ/hr 
Output 
6.3 kW 
Heating Capacity (cool climate) 
69m² 
Colour 
Charcoal grey 
Heating type 
Convection/Radiant 
Circuit resistance (overall A - N) 
27.1 ohms 
Fan resistance 
12 ohms 
Gas valve gas connection 
3/8”NPT 
Gas valve resistance (A – N) 
13 Mega-ohms (using multimeter – do not megger) 
Transformer resistances 
Primary 27 ohms / Secondary 13.3 ohms 
Transformer voltages 
Primary 240 VAC / Secondary 115 VAC 
Thermopile 1 voltage (generated) 
500mVDC 
Thermopile 2 voltage (generated) 
280mVDC 
Pilot flame adjustment level 
10 – 13mm vertically high 
Ignition plug gap 
3mm 
Heater external dimensions (mm) 
H 555 W 760 D 430 
H 810 W 660 D 495 
Weight 
44kg 
77kg 
Minimum flue length 
3.7m 
3m 
Maximum flue length 
10.7m 
12m 
Blocked flue switch cut out temp 
132ºC 
218ºC 
Installation method 
Inbuilt 
Freestanding 
Remote controller 
Included as standard 
Gas Pressures 
LHEC30 
RFSDV34 
Min gas inlet pressure - NG 
1.1 kPa 
Min gas inlet pressure - Propane 
2.75 kPa 
Max gas inlet pressure - NG 
3.5 kPa 
Max gas inlet pressure - Propane 
3.5 kPa 
Burner gas pressure - NG 
0.87 kPa 
Burner gas pressure - Propane 
2.5 kPa 
Minimum Clearances (mm) 
LHEC30 
RFSDV34 
Back 
N/A 
0 
Sides 
N/A 
305 
Floor 
N/A 
0 
Top 
N/A 
915 
Corner 
N/A 
0 
Mantle height 
610 above upper louvre 
N/A 
Mantle maximum depth 
200 