Specifications

TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
4
Specifications
Specification
LHEC30
RFSDV34
Power supply
240 VAC 50Hz
Electrical connection
10A 3 pin plug
Gas input NG
32 MJ/hr
Gas input P
32 MJ/hr
Output
6.3 kW
Heating Capacity (cool climate)
69
Colour
Charcoal grey
Heating type
Convection/Radiant
Circuit resistance (overall A - N)
27.1 ohms
Fan resistance
12 ohms
Gas valve gas connection
3/8”NPT
Gas valve resistance (A N)
13 Mega-ohms (using multimeter do not megger)
Transformer resistances
Primary 27 ohms / Secondary 13.3 ohms
Transformer voltages
Primary 240 VAC / Secondary 115 VAC
Thermopile 1 voltage (generated)
500mVDC
Thermopile 2 voltage (generated)
280mVDC
Pilot flame adjustment level
10 13mm vertically high
Ignition plug gap
3mm
Heater external dimensions (mm)
H 555 W 760 D 430
H 810 W 660 D 495
Weight
44kg
77kg
Minimum flue length
3.7m
3m
Maximum flue length
10.7m
12m
Blocked flue switch cut out temp
132ºC
218ºC
Installation method
Inbuilt
Freestanding
Remote controller
Included as standard
Gas Pressures
LHEC30
RFSDV34
Min gas inlet pressure - NG
1.1 kPa
Min gas inlet pressure - Propane
2.75 kPa
Max gas inlet pressure - NG
3.5 kPa
Max gas inlet pressure - Propane
3.5 kPa
Burner gas pressure - NG
0.87 kPa
Burner gas pressure - Propane
2.5 kPa
Minimum Clearances (mm)
LHEC30
RFSDV34
Back
N/A
0
Sides
N/A
305
Floor
N/A
0
Top
N/A
915
Corner
N/A
0
Mantle height
610 above upper louvre
N/A
Mantle maximum depth
200
N/A