Specifications
TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
35
Fault Finding Chart 8
Component Replacement Procedures – LHEC30
Removing the Glass Frame Assembly – LHCE30 (Procedure 1)
Only glass and gaskets approved by Raypak Australia may be used for
replacement. The use of substitute glass and/or gaskets will void all
warranties.
Under no circumstances is the log fire to be operated without the glass frame
assembly or with a broken glass panel or gasket. Replacement of the glass
including the gasket is to be performed by a licensed and qualified person.
If the log fire has been recently operated the glass frame assembly will be
extremely hot. A serious and significant burn hazard exists. Ensure the log
fire has sufficiently cooled before attempting to remove the front glass frame
assembly.
1. Turn pilotstat knob to the „OFF‟ position.
2. Open the hinged front lower louvre located below glass frame then lift up and remove
lower louvre.
3. Remove two glass frame retaining screws located on bottom corners of glass frame
assembly then lift bottom of glass frame assembly out slightly and up to remove.
4. Complete reassembly in reverse order of above.
NO
Is
the fan
obstructed?
8
YES
YES Remove fan obstruction.
Is the
noise a creaking
and/or cracking
noise?
NO
YES
It is normal for heating
appliances fabricated from
steel to give off some
expansion and/or contraction
noises during the start-up or
cool down cycle.
Is the
fan or fan motor
motor noisy?
Replace fan assembly.
Check for vibration noise
caused by loose component.
NO