Specifications

TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
34
Fault Finding Chart 7
(1)
Notes
(1) Log fire will light and burner will operate on high
flame without 240V power supply however fan and
some remote controller functions will not operate.
7
Test 5
The local/remote
selector switch is
located on the gas
valve
Replace gas valve.
NO
Does
the fan work
when local/remote
switch is set to
„local‟?
YES
Is
240V AC present
at the power
point?
Has
the power
circuit fuse
blown?
NO
No power supply. Advise
customer to have electrician
check household power
circuit.
NO
Did
the power
circuit fuse
blow?
Replace fuse
or reset circuit
breaker.
6.3
YES
YES
Blown fuse replaced.
Possible overloading of
power circuit. Check Log
fire operation and advise
customer.
NO
Is 240V AC
present at the
transformer?
YES
Replace cord set.NO
YES
(1)
Plug log fire into power
point and switch on.
NO
Is 115V AC
present at the
transformer?
Replace transformer.NO
YES
Is the
fans winding
resistance
correct?
YES Replace fan assembly.NO
Test 6
YES
Is the
log fire plugged
into power point &
switched on?
Replace remote controller
batteries.
YES
Switch the local/remote
selector switch to „remote‟.
NO
Does
remote
controller
work?
(1)
Does
gas valve LED
indicate 3 or 8
flashes?
YES
2.1
NO
Fault rectified.
Replace gas valve.
YES
NO
Are
remote
controllers
batteries
flat?
Refer to „Recognition
Signal‟ in the section on
„Remote Controller‟.
Re-teach the gas valve the
remote controller frequency.
YES
Reconnect antenna.
Move antenna away from
any metal (earth).
Is antenna
correctly
installed?
Remote controller antenna
must be firmly connected,
hanging in free air and not
touching any metal (earth)
NO
Is
local/remote
switch set on
„Local‟?
YES
The local/remote selector
switch must be set on
„remote‟ for the remote
controller to operate the log
fire. Set switch to „remote‟.
NO
The local/remote selector
switch is located on the
gas valve
Test 7A for LHEC30
or Test 7B for RFSDV34
Test 8A for LHEC30
or Test 8B for RFSDV34