Specifications

TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
32
Fault Finding Chart 6.1 & 6.2
(1)
6.1
Is RC
fan level set on
0?
YES
6.2
Remote controller fan level
was set on 0. It must be set
on 1 6 for fan to operate.
Room temp must be > or =
to set temp for fan to
operate.
YES
7
Increase RC set
temp to 1º > room temp &
wait for 1 minute.
Is
RC fan level
0?
Replace remote controllerYES
NO
NO
Note: RC = Remote
Controller
Is
RC fan level
0?
Is RC
room temp > or
= set temp?
NO
Is RC
room temp =
set temp?
YES
YES
NO
Room temp was = set temp
& remote controller turned
fan off. Normal operation.
Did
the fan come
on?
YES
NO
YES
Increase RC fan
level to 6.
Did
the fan come
on?
Notes
(1) This refers to the wording next to the
fan icon (remote controller on auto
but fan manually overridden)
(2) When room temp = set temp fan may
be on or off.
(2)
(2) (2)
NO
NO
Is
RC fan setting
on manual?
NO
YES
(1)