Specifications
TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
31
Fault Finding Tests 7A – 8B
Test 7A – LHEC30
Test 7B – RFSDV34
Warning - Ensure power is
isolated before conducting this
test.
Mark and disconnect wiring from the
transformer and using a multimeter on the
ohms scale, measure between terminals 1
and 5 of the transformer (transformers
primary winding).
The reading should be approximately 27
ohms.
Warning - Ensure power is
isolated before conducting this
test.
Mark and disconnect wiring from the
transformer and using a multimeter on the
ohms scale, measure between terminals 1
and 5 of the transformer (transformers
primary winding).
The reading should be approximately 27
ohms.
Test 8A – LHEC30
Test 8B – RFSDV34
Warning - Ensure power is
isolated before conducting this
test.
Mark and disconnect wiring from the
transformer and using a multimeter on the
ohms scale, measure between terminals 2
and 4 of the transformer (transformers
secondary winding).
The reading should be approximately 13
ohms.
Warning - Ensure power is
isolated before conducting this
test.
Mark and disconnect wiring from the
transformer and using a multimeter on the
ohms scale, measure between terminals 2
and 4 of the transformer (transformers
secondary winding).
The reading should be approximately 13
ohms.