Specifications

TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
31
Fault Finding Tests 7A 8B
Test 7A LHEC30
Test 7B RFSDV34
Warning - Ensure power is
isolated before conducting this
test.
Mark and disconnect wiring from the
transformer and using a multimeter on the
ohms scale, measure between terminals 1
and 5 of the transformer (transformers
primary winding).
The reading should be approximately 27
ohms.
Warning - Ensure power is
isolated before conducting this
test.
Mark and disconnect wiring from the
transformer and using a multimeter on the
ohms scale, measure between terminals 1
and 5 of the transformer (transformers
primary winding).
The reading should be approximately 27
ohms.
Test 8A LHEC30
Test 8B RFSDV34
Warning - Ensure power is
isolated before conducting this
test.
Mark and disconnect wiring from the
transformer and using a multimeter on the
ohms scale, measure between terminals 2
and 4 of the transformer (transformers
secondary winding).
The reading should be approximately 13
ohms.
Warning - Ensure power is
isolated before conducting this
test.
Mark and disconnect wiring from the
transformer and using a multimeter on the
ohms scale, measure between terminals 2
and 4 of the transformer (transformers
secondary winding).
The reading should be approximately 13
ohms.