Specifications

TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
29
Fault Finding Chart 6
Notes
(1) Log fire will light and burner will operate on
high flame without 240V power supply however
fan and some remote controller functions will not
operate.
6
Test 5
The local/remote selector switch
is located on the gas valve
Replace gas valve.
NO
Does
fan not work
only when local/remote
switch is set to
„remote‟?
Remote
controller
setting
6.1
6.2
ON (manual)
OFF
AUTO
The remote controller must
be set to „On‟ or „Auto‟ mode
for the fan to operate.
YES
Is
240V AC present
at the power
point?
Has
the power
circuit fuse
blown?
NO
No power supply. Advise
customer to have electrician
check household power
circuit.
NO
Did
the power
circuit fuse
blow?
Replace fuse or reset
circuit breaker.
6.3
YES
YES
Blown fuse replaced.
Possible overloading of
power circuit. Check log
fire operation and advise
customer.
NO
Is 240V AC
present at the
transformer?
YES
Replace cord set.NO
YES
(1)
Plug Log fire into power
point and switch on.
NO
Is 115V AC
present at the
transformer?
Replace transformer.NO
YES
Is the
fans winding
resistance
correct?
YES
Replace fan assembly.NO
Test 6
(1)
YES
Is
Log fire plugged
into power point &
switched on?
Test 8A for LHEC30
or Test 8B for RFSDV34
Test 7A for LHEC30
or Test 7B for RFSDV34