Specifications

TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
23
Fault Finding Chart 2.1 & 2.2
Refer to section
on „Fluing‟
(1)
Is the
gas valve LED
indicating 3
flashes?
2.1
YES
Reconnect thermopile spade
terminal(s) firmly.
Are
all thermopile
spade terminals
pushed on
firmly?
Is
blocked
flue switch
open?
Disconnect
power
YES
NO
Is
flue blocked
or partially
blocked?
YES
Replace blocked flue switch
YES
NO
Swap thermopile 1 wires with
thermopile 2 wires at gas valve.
Ensure white wires are connected
to terminals with white dots next
to them (refer to wiring diagram).
Restore power
Is the
gas valve LED
indicating 3
flashes?
Replace both thermopilesYES
Fault rectified.NO
Is
local/remote
switch set on
„Local‟?
The local/remote selector switch
is located on the gas valve
No: Error code
8 is indicated
(8 flashes)
Replace the gas valve.NO
YES
Wait 2 minutes.
Is the
gas valve LED
indicating 8
flashes?
Fault rectified.NO
Replace the gas valve.YES
Switch the local/remote
selector switch to remote.
Is antenna
correctly
installed?
Refer to „Recognition Signal‟ in
the section on „Remote Controller‟
Re-teach the gas valve the
remote controller frequency.
Reconnect antenna.
Move antenna away from
any metal (earth).
NO
Remote controller antenna must be
firmly connected, hanging in free air
and not touching any metal (earth)
Is
blocked
flue switch
open?
Flue blockage cleared.
Blocked flue switch reset.
Unblock &
clean flue.
For RSFDV34 reset
blocked flue switch by
pressing reset button on
rear of switch. LHEC30
is auto reset.
YES
NO
NO
YES
2.2
Notes
(1) RFSDV34 blocked flue switch
can be manually reset < 218ºC.
LHEC30 auto resets < 132ºC.
Test 2A for
LHEC30
or
Test 2B for
RFSDV34
Test 2A for LHEC30
or Test 2B for
RFSDV34
Is flue
length and/or
cowl location
correct?
Rectify flue and/or
flue cowl fault.
NO
YES