Specifications
TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
21
Fault Finding Chart 1
Fault Finding Test 1
Test 1
Warning - Ensure power is isolated before conducting this test.
1. Cut ignition plug wire 100mm before electrical joining connector and strip end to
expose conductor.
2. Hold tip of exposed conductor 2 – 3mm away from any unpainted metal part of
log fire frame (earth).
3. Push and release piezo igniter. A spark should be generated between tip of
exposed conductor and metal frame every time the piezo igniter push button is
operated.
4. Rejoin wire with an insulated electrical connector when testing is complete.
YES
Does
gas valve LED
indicate 1
flash?
1
Wait until the gas
valve LED stops
flashing
Can
the pilotstat knob
be operated?
YES
NO
Thermocouples were still hot
from previous operation.
Normal operation
NO Replace the gas valve
Replace the gas valve
Does
gas valve LED
indicate 3 or 8
flashes?
NO
2.1
YES