Specifications

TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
14
If the set point temperature is now higher than the room temperature the optimum flame
and fan levels will automatically be selected to reach or maintain the set point temperature.
These levels (of modulation) will depend upon the differential between the set point
temperature and the room temperature i.e. larger differential = higher flame and fan levels.
For example: If there is a differential of 2.5 degrees the controller may automatically
determined that a flame height of 6 and a fan speed of 6 is required. When the room
temperature has reached the set point temperature the controller may then automatically
determine that a flame height of 1 and fan speed of 1 is required to maintain this
temperature.
Fan Override: It should be noted that when in auto mode the fan speed will be the same
as, and will automatically rise and fall with the flame speed. If a lower or higher fan speed
is desired, the fan speed can be overridden by pressing and releasing the fan button and
then adjusting the fan speed manually using the up or down arrow buttons as previously
explained.
If the fan speed has been overridden in this manner „Auto will be displayed next to the
flame icon and „Manual‟ will be displayed next to the fan icon.
To revert to the auto fan setting, cycle through to „Auto‟ by pressing and releasing the
mode button until „Auto appears for the second time („Auto will first appear when the
mode button is pressed and released however you must cycle past this until „Auto‟
appears again).
Off Mode
Press and release the „mode‟ button until „OFF‟ is displayed. After a two second delay from
the operation of any button the burner and fan will turn off and room temperature and
OFF will be displayed on the controller.
Other Functions
Temperature Unit of Measurement: The temperature unit of measurement can be
changed from ºC to ºF and vice versa. To do this press and hold down the up and down
arrow buttons simultaneously until the display value changes (approximately three
seconds). This function may be performed whist the remote controller is in any mode.
Countdown Timer: A countdown timer is available and can be activated when the remote
control is in the „ON‟ (Manual) or „AUTO‟ mode. The countdown timer can be set from 10
minutes to 2 hours and will turn the burner and fan off when it reaches zero.
To activate the countdown timer first ensure the remote is in „ON‟ or „AUTO‟ mode then
press and release the timer button.
The timer time can then be adjusted up or down in ten minute increments by pushing and
releasing the up or down arrow buttons. After a 2 second delay the time will be accepted.
The display will then revert to the relevant setting (ON or AUTO) and the timer time will be
displayed along with the usual information.
When the countdown timer reaches zero the burner and fan will turn off and the remote
control will revert from „ON‟ or „AUTO‟ mode to „OFF” mode.
The countdown timer can be cancelled at any time after activation by pressing and
releasing the countdown timer button until -:-- is shown on the display. After a two second
delay the display will revert to the previously used setting and the delay timer will be
cancelled.