Lighting Instructions
1. Ensure the LOCAL/REMOTE selector switch on the gas valve is set on LOCAL.
2. Remove the log fire glass door.
3. Turn the pilotstat knob to the PILOT position, push the pilotstat knob down and hold it in
the depressed position. The pilot valve is now open and will allow gas to flow to the
pilot.
4. Push and release the piezo igniter until the pilot flame is established. When lit, continue
to hold the pilotstat knob in the depressed position until the gas valve LED flashes (this
will take from several seconds (hot start) to one minute (cold start). When the LED is
flashing the thermopile is generating sufficient voltage to hold the gas valve open and
the pilotstat knob can then be released. If the pilot goes out repeat steps 3 to 4 until lit.
5. Replace the glass door.
6. Turn the pilotstat knob to the ON position. The burner will now light on full flame and the
fan will operate on full speed.
7. For remote control operation turn the LOCAL/REMOTE selector switch to the REMOTE
position.
8. To turn the log fire OFF push in the pilotstat knob slightly and rotate to the OFF position.
It should be noted that the pilotstat knob cannot be turned from the OFF to PILOT position
whilst the gas valve LED is flashing. This is a safety device which may occur if the log fire
has been switched off after or during operation and is due to the thermopiles generating a
voltage from residual heat. When the thermopiles cool (approx 30 seconds) the pilotstat
knob may be operated as normal.
Remote Controller Operation
Both log fires are supplied with
and can be operated by a remote
controller which is powered by
three AAA batteries.
The remote controller will not
turn the pilot or gas valve ON or
OFF however it can control the
burner flame height and fan
speed manually or automatically.
Recognition Signal
Upon initial use of the remote controller a recognition signal operation is required to be
performed between the gas valve and the remote controller.
To perform this procedure switch the LOCAL/REMOTE selector switch on the gas valve to
the REMOTE position and press the fan or flame button on the remote controller within 30
seconds. The LED on the gas valve will flash once indicating the signal has been received.
The gas valve has now been programmed to the remote controller frequency and may be
operated manually (ON mode) or automatically (AUTO mode) by the remote controller.
Note: The LOCAL/REMOTE selector switch on the gas valve must be in the REMOTE
position for the remote controller to operate the log fire (except fan speed).
Remote controller
operational buttons