INSTALLER/CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. Freestanding Direct Vent Fireplace Models: RFSDV24, RFSDV34 FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THIS APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions General Information, Warnings, Cautions ................
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Installation & Operating Instructions This gas fireplace should be installed by a qualified installer in accordance with local building codes and with current CSAB149.1 Installation codes for Gas Burning Appliances and Equipment. If the unit is being installed in a mobile home, the installation should comply with the current CAN/USA Z240.4 code. For USA Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Installation & Operating Instructions Requirements for the Commonwealth of Massachusetts All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Fireplace Dimensions H J I K G B D F E A C Fig. 1 Fireplace specifications and framing dimensions. Ref.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Locating Your Fireplace Gas Specifications 12” (305 mm) A 12” (305 mm) Model RFSDV24RN RFSDV24RP RFSDV34RFN RFSDV34RFP D B C FP1620 Fig. 2 Locate gas fireplace. B) Room Divider* FP1620 E) Flatlocate on wall corner freestanding C) Island Note (Fig. 2): *(A) and (B) must maintain a 12” (305 mm) clearance between the wall and side glass of fireplace. There is a minimum vertical rise required for the venting, which varies depending on the application.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace 1/2” Gas Supply Screw (through existing hole) Screw 1/2” x 3/8” Reducer ON/OFF Switch Assembly 3/8” Nipple Clips 3/8” Union 3/8” Nipple 3/8” x 3/8” Shut-Off Valve CFM106 3/8” Nipple Wiring for Millivolt Gas Valves Fig. 3 Typical gas line connection. Installation of Remote Switch CFM106 for RN/RP Gas Valve Typical Gas Line Connection NOTES: The remote 9-29-00ON/OFF switch cannot be fitted to units using the Honeywell Radio Frequency control valve.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL G V H A N N D L V E C B V F B ����� ������ B V Ope Operable rable V B B B J X X AIR SUPPLY INLET M I A CFM145a V VENT TERMINATION V V Fixed Closed C = Clearance to permanently closed window D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2’ (610mm) from the center line of the terminal E = Clearance to unv
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner G= Combustible 6" (152 mm) G F= Combustible 6" (152 mm) Noncombustible 2" (51 mm) V Noncombustible 2" (51 mm) V C V E O F Balcony with perpendicular side wall Balcony with no side wall D C E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4 m) Min.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace How to Use the Vent Graph Vertical Sidewall Applications The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system. 1. Determine the height of the center of the horizontal vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph (Fig. 8), locate the point intersecting with the slanted graph line.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Example: Elbow 1 Elbow 2 Elbow 3 Elbow 4 Total angular variation = = = = = 90° 45° 45° 90° 270° 7.5ʼ (2286 mm) 1 + 2 + 3 + 4 = 270° A + B =17’ (5.2 m) Max. FP1496 Fig. 10 90° elbow used in horizontal vent run. FSDV 2 elbow 20 appl. 20ʼ (6 m) rev 0602 rjs 7.5ʼ (2. m) FP1239 Fig. 12 Maximum elbow usage.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace STEP 2 Measure wall thickness and cut zero clearance sleeve parts to proper length (MAXIMUM 12”/305 mm). Assemble sleeve and attach to firestop with #8 sheet metal screws (supplied). Install firestop assembly. (Fig. 14) Zero clearance sleeve is only required for combustible walls. Max. Length 12” (305mm) Adjustable Zero Clearance Sleeve #8 Screws (2) #8 Screws (2) #8 Screws (2) Bead of Sealant FP1509 Fig. 16 Horizontal vent length.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Below Grade Installations When it is not possible to meet the required vent terminal clearances of 12” (305 mm) above grade level a snorkel vent kit is recommended. It allows installation depth of down to 7” (178 mm) below grade level. The 7” is measured from the center of the horizontal vent pipe as it penetrates through the wall. If venting system is installed below ground, we recommend a window well with adequate and proper drainage.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Do not back fill around snorkel. A clearance of at least 4” (102 mm) must be maintained between snorkel and the soil. If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as protruding wall face. (Fig. 21) Max. 8’ (2.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace 7. Install roof support (Fig. 22) and roof flashing making sure upper flange of flashing is below the shingles. (Fig. 25) 8. Install appropriate pipe sections until the venting is above the flashing. (Fig. 25) 9. Install storm collar and seal around the pipe. 10. Add additional vent lengths for proper height. (Fig. 23) 11. Apply high temperature sealant to 4” and 7” collars.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Twist Lock Venting Components Starter Kit - Model 7TFSMSK Starter Kit - Model 7TFSDVSK Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A, order 1/12 to 6/12 roof pitch for 7TDVSKV-B, order 7/12 to 12/12 roof pitch for 7TDSKV-F, order flat roof Starter Kit - Model 7TFSDVSKS - Snorkel Kit for below grade installation 584B Vent components Starter Kit 2/25/99 djt 584C Vent components 584D 45 degree elbow Vent Components 90 degree elbow 2/25/99 djt 2/
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Operating Instructions Glass Information Only glass approved by CFM Corporation may be used for replacement. The use of substitute glass will void all product warranties. Take care to avoid breaking the glass. Under no circumstances is this fireplace to be operated without the front glass or with a broken glass. Replacement of the glass (with gasket) as supplied by the manufacturer should be done by a licensed qualified service person.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace For Model RFSDV34 (Refer to Fig. 28) Figure 27 RFSDV24 1. Remove window frame assembly. (Refer to Window Frame Assembly Removal section) 2. Remove logs from packaging. As with all plastic items - these logs and their packaging are not toys and should be kept away from children and infants. 3.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Flame & Temperature Adjustment Flame Characteristics It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the pictorials illustrated below (Fig. 30-31). RN/RP Models Turn counterclockwise to decrease flame height �� For units equipped with ‘HI/LO’ valves the flame adjustment is accomplished by rotating the ‘HI/LO’ adjustment knob located near the center of the gas control valve. (Fig.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater area for gas.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Instructions for RF Comfort Control Valve The Comfort Control Valve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal. Operation 1. If the manual switch is in remote position, switch it to LOCAL. (Fig. 32) 2. Turn the pilotstat knob counterclockwise from OFF to the PILOT position, push the knob down, and hold in position.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Delay Timer Mode Pilot Assembly The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes. Fan Auto Mode In the AUTO mode, the room temperature, set temperature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace 2. Slide the Remote/Local switch to REMOTE and teach the valve a transmitter (refer to Item 6, page 32). The Error Code will clear itself after approximately 1¹⁄₂ minutes and return to normal operation. LED Count Service Action Auto Path If the manual switch is set to REMOTE, press the mode button to display AUTO on the transmitter.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Comfort Valve system control sequence of operation with transmitter Set manual switch to local or remote Five minute wait period Light pilot burner Did the LED stop blinking? Yes Review LED failure analysis Release pilotstat knob Yes Turn pilotstat knob from PILOT to ON Move switch from local to remote. Press any key on transmitter.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Troubleshooting Honeywell VS8420 Standing Pilot Remove Glass Panel Before Servicing. START Gas Supply ON CHECK NO • Supply line hooked up • Shutoff valve open NO • Lockout has engaged. Wait 60 seconds and try again. • For spark at electrode while depressing Piezo - 1/8" gap to pilot hood needed. • All wiring connections • Replace Piezo ignitor NO • For air in lines • Thermopile needs a minimum 325mV. Adjust pilot flame height.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and refit the logs as per the instructions in this manual. Always handle the logs with care as they are fragile and may also be hot if the fireplace has been in use.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace 2 RFSDV34 RFSDV24 4 1e 1g 1f 3 1h 1d 1b 1c 1b 1b 13a 34 1a 32 8a/b 39 13b 9a/b 13b 14 10 27 17 11a 9c/d 40 11b 30 11a 24 20 18c/d 14 21 29 19 OFF PILOT ADJ ON P I O H 18a/b L I LO 15 T 28 14 37 OT OFF 38 ON L PI 31 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace RFSDV24/34 Ref. 1f. 1g. 1h. 2. 3. 4. 5a. 5b. 5c. 5d. 6a. 6b. 7a. 7b. 8a. 8b. 9a. 9b. 9c. 9d. 10. 11a. 11b. 12. 13a. 13b. 14. 15. 16. 17. 18a. 18b. 18c. 18d. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 28 (continued) Description Log - Top Right Log - Rear Left Log - Rear Right Lava Rock Burner Housing Assembly w/tiles Ceramic Tile (single) Orifice, Main Burner - Nat. (not shown) Orifice, Main Burner - Prop. (not shown) Orifice, Front Burner - Nat.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace RFSDV24/34 Ref. 32. 33. 34. 35. 36. 37. 38. 39. 40.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace For Use in Mobile Homes: Model RFSDV34RMH This appliance may be installed as an OEM installation in a manufactured (mobile) home and must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installation in Mobile Homes, CAN/CSA Z240 MH. This appliance is only for use with the type(s) of gas indicated on the rating plate.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Optional Accessories Fan Kits Disconnect the power supply before servicing the fan. Refer to Figure 35 for rewiring replacement components. FK24 Fan Assembly This auxiliary fan system increases the efficiency of the circulation of the heating air. The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace Installation Procedure Optional Gold Trim Kit A decorative gold-plated window trim kit, Model RFSDV24TKG is available for the RFSDV24 Freestanding Fireplace. Kit contents: (1) Gold-plated window trim (4) Magnets Installation Procedure 1. Unpack the kit and confirm all parts are present. 2. It is very important to remove all the protective plastic wrap from the gold window trim. 3. Attach the magnets to the trim. (Fig. 39) 4.
RFSDV24/34 Freestanding Direct Vent Gas Fireplace 10003550 33
RFSDV24/34 Freestanding Direct Vent Gas Fireplace 34 10003550
RFSDV24/34 Freestanding Direct Vent Gas Fireplace LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.
Efficiency Ratings Model RFSDV24RN RFSDV24RP RFSDV24RFN RFSDV24RFP RFSDV24EN RFSDV24EP RFSDV34RN RFSDV34RP RFSDV34RFN RFSDV34RFP RFSDV34EN RFSDV34EP EnerGuide Ratings Fireplace Efficiency (%) 65.3 65.3 65.3 65.3 68.7 68.7 72.1 72.1 72.1 72.1 75.2 75.2 CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.