Operating instructions

8
ODGSR Series Outdoor Gas Fireplace
20007114
FP1416
ODUVSR
part id
11/24/03 djt
Nailing
Flange
ValveAccessPanel
Firebox
Grate
Screen
Standoff
Surround
Gas
LineAc-
cess
FP1416
Fig. 8Partsidentication.
*Donotinstall
headeruntilunit
isinplace.
FP1416
ODUVSR
part id
11/24/03 djt
NailingFlange
ValveAccessPanel
Firebox
Grate
Screen
Standoff
Surround
Gas
Line
Access
*Donotinstall
headeruntilunit
isinplace.
Interiorsidesofanexteriorchase
shouldbeweatherproof
FP1644
Fig. 9Exteriorchaseinstallation.
Gas Line Installation
Thisappliancemustbeisolatedfromthegassupplypiping
systembyclosingitsindividualmanualshutoffvalveduring
anypressureequaltoorlessthan1/2psig(3.45kPa).
Theapplianceanditsindividualshutoffvalvemustbedis-
connectedfromthegassupplypipingsystemduringany
pressuretestingofthatsystemattestpressuresinexcess
of1/2psig(3.45kPa).
Ifgaspipingfromthesourcetotheappliancelocationhas
notbeenaccomplished,installtherequiredpipe.Consult
localplumbingcodetoassureproperpipesize.
Thegaspipelinecanbebroughtinthroughtherightsideof
theappliance.Aknockoutisprovidedtoallowforthegas
pipeinstallationandtestingofanygasconnection.
NOTE: The gas line connection can be made with 3/8"
coppertubingapprovedforpropaneornaturalgas,1/2"
rigidpipeoranapprovedexconnector,thenreducedto
3/8"totheappliance.Becausesomemunicipalitieshave
someadditionallocalcodes,it isalwaysbesttoconsult
yourlocalauthority.
U.S.:ConsultthecurrentNationalFuelGasCode,ANSI
Z223.1/NFPA54.
Canada:CSA-B149.1installationcode.
Testforleaks.Usea50/50solutionofliquidsoapandwater
totestforleaksatgasttingsandjoints.Applywater/soap
solutionwithbrushonly-donotoverapply. NEVER test
withanopename.
Thegascontrolisequipped withacapturedscrewtype
pressuretestpoint,thereforeitisnotnecessarytoprovide
a1/8"testpointupstreamofthecontrol.
Whenusingcopperorexconnectoruseonlyapproved
ttings.Always provide a unionsothatgaslinecanbe
easilydisconnectedforburnerorfanservicing.Seegas
specicationforpressuredetailsandratings.NOTE:Ifex
connectorisused,itmustbekeptinsideoftheappliance.
(Fig.10)
FP598
Fig. 10 Typicalgassupplyinstallation.
GF598
nvb GAS SUPPLY INSTALL
12/4/97
1/2"GasSupply
1/2"x3/8"Shut-offValve
3/8"Nipple
3/8"Union
3/8"Nipple