Gas Inlet & Manifold Pressures
Natural LP
MinimumInletPressure 5.5”w.c. 11.0”w.c.
MaximumInletPressure 14.0”w.c. 14.0”w.c.
ManifoldPressure 3.5”w.c. 10.0”w.c.
Gas Specication
Max. Min.
Model Fuel Gas Control Input Input
ODGSR36ARN Nat. MillivoltHi/Lo 60,000 42,600
ODGSR36ARP Prop. MillivoltHi/Lo 60,000 44,000
ODGSR42ARN Nat. MillivoltHi/Lo 60,000 42,600
ODGSR42ARP Prop. MillivoltHi/Lo 60,000 44,000
High Elevations
Input ratings are shown in BTU per hour and are
certied without deration from elevations up to 4,500
feet (1,370 m) above sea level.
Nuisance outages may occur at altitudes above 4,500
feet (1,370 m) if dirt, dust, lint and/or cobwebs are
allowed to accumulate on burner and/or ODS pilot.
Monthly inspection and cleaning is recommended
for altitudes above 4,500 feet (1,370 m)
For elevations above 4,500 feet (1,370 m), installa-
tions must be in accordance with the current ANSI
Z223.1/NFPA 54 and/or local codes having jurisdic-
tion.
Valve Access
Valveaccesscanbeaccomplishedinoneoftwoways:
1. Removethefrontpaneljustbelowthefrontofthehearth
pan.This is accomplished by lifting on the panel.To
replacethevalveaccesspanellineupthetwopinswith
theholesinthesurroundbottomandpushthepanel
overthefrontofthehearthpan.(Fig.5)
2. LiftthebrickwiththeVermontCastingsGrouplogoon
it.(Fig.6)
ODGSR36A / ODGSR42A
Certied to
ANSI Z21.97
Outdoor Decorative Gas Appliances
CGA CR97-003
Outdoor Gas Fireplaces
FP1414
ODUVSR
valve access
11/24/03 djt
FP1414
Fig. 5Valveaccess.
FP1415
lift brick access
11/24/03 djt
VermontCast-
ingsGroup
LogoBrick
Fig. 6Liftbrickwithlogoonittoaccessvalve.
FP1415
1/2” (13 mm)
FP1642a
concrete install
9/06
NOTE:Wheninstallationis
onahard,atsurface(such
asconcrete),thesurface
mustbesloped1/4"perfoot
awayfromanystructure.
Blocking
Hard,FlatSurface
(i.e.concrete)
FP1642a