Owner`s manual

20013055 7/05 Rev. 0
7
A. Gas Supply Connection
Ensure ttings are of the appropriate size and type on the
gas line connection. If the tubing has to be cut to length be
sure to use the proper cutting and aring tool. Also, be care-
ful not to crimp the tubing while bending. If the tubing be-
comes crimped, do not use for installation.
Fire Risk
Explosion Risk
Verify inlet pressures.
High p r essure ma y cau se o v erfire
condition.
Low pressure may cause explosion.
Install regulator upstream of valve if line
pressure is greater than 1/2 psig.
WARNING
3
Appliance Preparation
B. Convert to Right Side Gas Piping
Remove black cap from right side.
Remove two pilot head screws.
Remove two pilot bracket screws.
Detach thermocouple and pilot from control valve.
Remove the control valve from the left side of the burner
pan and replace on right, upside down.
Note: Prior to installing the valve, use Teon tape or joint
compound on the male threads.
Reinstall pilot bracket on right side of burner.
Reinstall pilot assembly to pilot bracket.
Reattach pilot tube and thermocouple to control valve.
Reinstall black cap removed from right side of burner to
left side.
Install valve shield.
Note: An individual manual shutoff valve (not supplied) is
required when installing this appliance. Check local codes
for location of shut off valve.
Note: Have the gas supply line installed in accordance
with local building codes, if any. If not, follow ANSI 223.1.
Installation should be done by a qualied installer approved
and/or licensed as required by the locality. (In the Common-
wealth of Massachusetts installation must be performed by
a licensed plumber or gas tter.)
Note: A listed (and Commonwealth of Massachusetts
approved) 1/2 in. (13 mm) T-handle manual shut-off valve
and exible gas connector are connected to the 1/2 in.
(13 mm) control valve inlet.
If substituting for these components, please consult
local codes for compliance.
WARNING
Gas Leak Risk
Support control when attaching pipe to
prevent bending gas line.
WARNING
Fire Risk
Explosion Risk
Gas build-up during line purge may
ignite.
Purge should be performed by qualied
technician.
Ensure adequate ventilation.
Ensure there are no ignition sources such
as sparks or open ames.
Fire Risk
Explosion Risk
Personal Injury Risk
An explosion could occur if a connection is
made directly to an unregulated propane (LP)
tank.
WARNING
Certied joint compound ot Teon tape must be used on all
threaded male connections to ensure a tight seal.