Operating instructions

75D0004 9
MLDV Series Gas Fireplace
The replace must be secured to the oor and/or to framing
studs as shown in Figure 6. Use two () wood screws or
masonry/ concrete screws to secure replace to the oor.
Use four (4) screws to attach replace to framing. The side
nailing anges are 1/" or 5/8" to accommodate different
wall thickness.

FP1989
install fireplace
Figure 6 -
Secure Fireplace to Floor and
Framing Studs
Framing
Screws
Nailing Flange
Insulation Board

FP1989

   


 Any remote wiring (i.e. remote control, wall switch,
and optional fan) must be done prior to nal nishing to
avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel,
or other materials with a UL re rating of Zero) may be
used to cover the black painted face of the appliance. It is
permissible to bring combustible wall board to the top and
side edges of the black painted face. A 300°F minimum
adhesive may be used to attach facing materials to the
black surface. If joints between the nished wall and the
replace surround are sealed, a 300°F minimum sealant
material (General Electric RTV103 or equivalent) must be
used.