Operating instructions

18
75D0004
MLDV Series Gas Fireplace

FP1176
max 90 bends
Figure 20 -
Maximum Three (3) 90° Elbows
Per Installation
3 x 90°
Elbows
3 x 90°
Elbows
FP1176
Max 20"
Max 20"
36"
(914 mm)
Max.
36"
(914 mm)
Max.
FP1177
max horizontal run
Figure 21 -
Maximum Horizontal Run with No Rise
FP1177

 
       
        
     
    
    

If a 90° elbow is used in the horizontal vent run (level
height maintained) the horizontal vent length is reduced
by 36". Figure 23. This does not apply if the 90° elbows
are used to increase or redirect a vertical rise. Figure
22
 According to the vent graph (Page 17) the
maximum horizontal vent length in a system with a 7.5'
vertical rise is 20’ (6 m) and if a 90° elbow is required in the
horizontal vent it must be reduced to 17' (5.2 m).
In Figures 22 and 23 dimension A plus B must not be
greater than 17' (5. m).
Figure 23 -
Maximum Vent Run with Elbows
FP1959
A + B = 17' Maximum
Horizontal 90° Elbow = 3' Reduction
7'6"
10'
7'
FP1958
Horizontal run reduction
Figure 22 -
Horizontal Run Reduction
90°
7'6"
FP1958
The horizontal vent run refers to the total length of vent
pipe from the ue collar of the replace (or the top of the
Transition Elbow) to the face of the nished outside wall
or the mounting ange of the termination.
The maximum number of 90° elbows per side wall
installation is three (3). Figure 20
If a 90° elbow is tted directly on the top of the replace,
the maximum horizontal vent run before the termination
or a vertical rise is 36” (914 mm). Figure 21